![Toa A-5000 Series Software Instructions Download Page 25](http://html1.mh-extra.com/html/toa/a-5000-series/a-5000-series_software-instructions_1122182025.webp)
25
[Setting Procedures]
Step 1. Click the [Manual] button.
The button lights green, enabling the Mute function.
The indication “Mute contact” is displayed in the Trigger field.
Step 2. Click the input that uses the Manual Mute function.
The clicked input button lights orange, indicating that input can be muted. Multiple inputs can be
selected.
Step 3. Click the input button for which detailed parameters are set.
The detailed settings for the clicked input are displayed graphically.
Step 4. Set the reduction level by dragging the reduction level point up or down.
Step 5. Set the hold time by dragging the hold time point right or left.
Step 6. Set the fade-in time by dragging the fade-in time point right or left.
Step 7. Repeat Steps 3 – 6 to perform settings for all targeted inputs.
1
2
3
4
5