Application
External view of the controller
Fully automatic controller JOKER D
S2
P
M-RC
is designed to dynamically control the
stoker,
blower, central
heating circulation pump, feeding pump of the domestic hot water tank
and the four-way valve
.
Controller
maintains the set temperature in rooms with a wireless room panel according to the time programming.
Controller controls dynamically the amount of delivered fuel and the blower power.
It features a thermal switch-
off function to protect the boiler against overheating, and is equipped with an “anti-stop” and antibacterial
protection functions
.
The controller may prioritize domestic hot water and additionally prevent the tank and
radiators from excessive cooling resulting from insufficient boiler temperature. It distributes boiler capacity
among central heating and domestic hot water circuits in a dynamic way, in conformity with user's settings and
preferences. The user can also select timed programmes ensuring optimisation of energy consumption.
The return water sensor protects the boiler from temperature dropping too low.
Thanks to advanced control procedures, the temperature of domestic water and heated spaces is maintained at
desired levels, while the boiler operates in optimal conditions ensuring increased life expectancy.
The user can limit the number of controlled appliances thanks to flexible configuration of the menu and the main
control screen.
MAIN SCREEN - status of the appliances and boiler temperature setting.
In order to change settings of the boiler on the MAIN SCREEN press the knob (arrows flash)
and turn it to select the desired temperature. To validate, press the [SAVE] button or press
the knob.
To exit without saving, press the [EXIT] button.
current
temperatures*
current
status of
appliances
temperature
setting
for the boiler
hour
and date
parameter
m
enu
boiler temp
.
Examples of appliance status
C.H. pump switched o
n
C.H. timed programme "day temperature" active
C
.H. pump manual mode
Multifunction touch buttons
MAIN SCREEN
Knob used for:
-
switching parameters
and changing settings
(by turning)
-
selecting parameters
for editing and saving
changes (by pressing)
s
witching between monitored
devices and temperatures*
CH
blower active
1
Firma TMK sp.j.
62-300 Września
Szosa Witkowska 105
tel./fax +48 61 437 97 60
www.tmk.com.pl
w
orking mode
screen
*
s
toker helix animation means that the stoker is
feeding coal
21.
3
temp.behind
the
valve
the valve is being opened (
closed)
C.H. timed programme "day temperature" active
CH
boiler return
temp.
EN
w
orking mode
*CAUTION - Temperature of the stoker is displayed on the "manual mode"
screen of the stoker and blower - press [MODE], and then [MANUAL MODE].
MONITORING OF ALL ACTIVE DEVICES AND TEMPERATURES (SENSORS) IS AVAILABLE IN THE MENU
- parameter J