JOKER DS2PM-RC

Instruction and installation manual

Application

External view of the controller

Fully automatic controller JOKER D

S2

P

M-RC

 is designed to dynamically control the

 stoker,

 blower, central 

heating  circulation  pump,  feeding  pump  of  the  domestic  hot  water  tank

  and  the  four-way  valve

Controller 

maintains  the  set  temperature  in  rooms  with  a  wireless  room  panel  according  to  the  time  programming. 
Controller controls dynamically the amount of delivered fuel and the blower power. 

It features a thermal switch-

off  function  to  protect  the  boiler  against  overheating,  and  is  equipped  with  an  “anti-stop”  and  antibacterial 
protection functions

The controller may prioritize domestic hot water and additionally prevent the tank and 

radiators  from  excessive  cooling  resulting  from  insufficient  boiler  temperature.  It  distributes  boiler  capacity 
among central heating and domestic hot water circuits in a dynamic way, in conformity with user's settings and 
preferences.  The  user  can  also  select  timed  programmes  ensuring  optimisation  of  energy  consumption.

                 

The return water sensor protects the boiler from temperature dropping too low. 
Thanks to advanced control procedures, the temperature of domestic water and heated spaces is maintained at 
desired levels, while the boiler operates in optimal conditions ensuring increased life expectancy.
The user can limit the number of controlled appliances thanks to flexible configuration of the menu and the main 
control screen.

MAIN SCREEN - status of the appliances and boiler temperature setting.

In order to change settings of the boiler on the MAIN SCREEN press the knob (arrows flash) 
and turn it to select the desired temperature. To validate, press the [SAVE] button or press 
the knob. 
To exit without saving, press the [EXIT] button.

current
temperatures*

current
status of 
appliances

temperature
setting
for the boiler

hour 
and date

parameter

m

enu

boiler temp

.

Examples of appliance status

C.H. pump switched o

n

C.H. timed programme "day temperature" active

  

C

.H. pump manual mode  

Multifunction touch buttons

MAIN SCREEN

Knob used for:

switching parameters 

  

and changing settings

  

(by turning)

selecting parameters 

   

for editing and saving 

   

changes (by pressing)

s

witching between monitored 

devices and temperatures*

CH

blower active     

1

Firma TMK sp.j. 

62-300 Września 

Szosa Witkowska 105

tel./fax +48 61 437 97 60

www.tmk.com.pl

w

orking mode 

screen

*

  

s

toker helix animation means that the stoker is 

  

feeding coal

21.

3

temp.behind 

the 

valve

the valve is being opened (

      

closed) 

C.H. timed programme "day temperature" active 

CH

boiler return
temp.

EN

w

orking mode

*CAUTION - Temperature of the stoker is displayed on the "manual mode" 
screen of the stoker and blower - press [MODE], and then [MANUAL MODE].
MONITORING OF ALL ACTIVE DEVICES AND TEMPERATURES (SENSORS) IS AVAILABLE IN THE MENU 

 - parameter J

Summary of Contents for JOKER DS2PM-RC

Page 1: ...ed spaces is maintained at desired levels while the boiler operates in optimal conditions ensuring increased life expectancy The user can limit the number of controlled appliances thanks to flexible c...

Page 2: ...power supply Otherwise the pump may become damaged General technical data Supply voltage 230V 50Hz Maximum pump output 3x100VA 1x250VA stoker 1x5VA valve Anti stop function pump protection against jam...

Page 3: ...IN SCREEN START STOP manual mode current temperature of the boiler Turn the knob to set blower speed arrows are flashing 1 Installation of the boiler temperature sensor and thermal breaker switch Fix...

Page 4: ...t 6 hours from switching from the SUMMER mode to the WINTER mode the controller does not take into account the minimal temperature at the return to the boiler parameter E3 ALERTS The controller featur...

Page 5: ...45 C Boiler extinguish temperature cannot be higher than the difference of parameters A1 minus A2 minus 5 C A4 Fire up duration 10 480 min default 6 hours A5 low boiler temperature alert 0 50 C defau...

Page 6: ...the knob or using the dynamically appearing buttons Editing is confirmed by pressing the knob or the SAVE button Pressing EXIT will bring back the previous screen without saving any changes LIST OF P...

Page 7: ...o change parameters of the C H pump List of groups of parameters will appear on the screen Turn the knob right clockwise to select group D C H pump and then to select press the knob or the SELECT butt...

Page 8: ...ehind valve is programmable different temperatures can be set for every day and hour of the week parameter H1 The central heating timed programme in use is displayed on the MAIN SCREEN between the CH...

Page 9: ...valve E2a E2b or E2c above the corresponding E1a E1b or E1c max temp behind valve results in both settings becoming equal E2a day 1 99 C default 35 C E2b night 1 99 C default 20 C E2c economy 1 99 C d...

Page 10: ...on if 1 the set temperature of domestic hot water has not been achieved and 2 when the temperature at the C H boiler is higher than that inside of the hot water tank by the parameter F4 protection of...

Page 11: ...take into account the minimal temperature at the return to the boiler parameter E3 F4 DHW tank protection from cooling down 0 15 C default setting 5 C F5 Minimal temperature of the CH boiler at which...

Page 12: ...l temperature behind valve is edited H high means that room temperature has not been reached and maximal temperature behind valve is edited Pressing the or button again will further increase or decrea...

Page 13: ...If NO has been selected oker controller operation with is deactivated LIST OF ROOM PANEL PARAMETERS G1 Room temperatures G2 Precision of room temperature control hysteresis 0 1 0 5 C default setting 0...

Page 14: ...elected day to another day of the week which you select with the knob Press SELECT or the knob Press EDIT or the knob In this screen turn the knob to select time interval to be edited Press NEXT or th...

Page 15: ...of coal consumption COAL CONSUMPTION PARAMETER MENU group I COAL CONSUMPTION SETTINGS CAUTION It is advisable to verify the estimation of coal consumption performed by the controller from time to time...

Page 16: ...zech CAUTION Return to default settings does not concern language K8 Information about the controller model software version 5 1 6 0 read only K9 Contrast of the display 1 31 default setting 12 CAUTIO...

Page 17: ...r defects which can be attributed to the manufacturer TMK sp j shall repair or replace the faulty controller with a defect free device within 14 working days from the date of returning the controller...

Reviews: