49-85/86/87 

Rev.E 

 

IMPORTANT SAFETY INSTRUCTIONS

 

Read all of these instructions carefully before operating the instrument. 

 

1.

 

Save these instructions for future reference. 

 
2.

 

Follow all warnings and instructions that are marked on the instrument.   

 
3.

 

Unplug the instrument from the wall outlet before cleaning.  Wipe the outside surfaces with a damp cloth 
only. 

 
4.

 

Do not use this instrument near water. 

 
5.

 

Do not place the instrument on an unstable cart, stand, or table. 

 

6.

 

Only operate the instrument from the type of power source indicated on the label. 
 

7.

 

For safety, this product is equipped with a three-wire grounding type plug.  This plug will only fit into a 
grounding type power outlet. If you are unable to insert the plug into the outlet, contact your electrician to 
replace the outlet with the proper type.  

Do not defeat the purpose of the grounding-type plug.

 

 
8.

 

Do not allow anything to rest on the power cord.  Do not locate this product where persons will walk on the 
cord.  

 
9.

 

If an extension cord is used with this product, make sure that the total ampere ratings of the product(s) 
plugged into the extension cord do not exceed the extension cord ampere rating.  Extension cords must have a 
minimum insulation rating of 600v. 

 

10.

 

Do not remove any panels from the tester.  Never push objects of any kind into any openings in the 

instrument’s c

overs. Failure to heed this warning could result in fire or electric shock.  Never spill liquid of 

any kind on the instrument. 

 
11.

 

Do not attempt to service this product yourself.  Opening or removing 
covers may expose you to dangerous high voltages.   
 

 
 

12.

 

At the end of its service life, dispose of the product according to the relevant statutory regulations. 

 

13.

 

Refer all servicing to Testing Machines’ Technical Support Staff: 

 

 

Testing Machines Inc. 

 

Customer Service Department 
40 McCullough Drive 
New Castle, DE 19720 USA 
Phone: (800) 678-3221 or (302) 613-5600 
Fax:  (302) 613-5619 
Email:  [email protected] 
Web:  www.testingmachines.com 

 
14.

 

Unplug the unit from the wall outlet and refer servicing to qualified service personnel under the following 
conditions: 

i

    When the power cord or plug is damaged or frayed. 

i

  If liquid has been spilled into the product. 

i

 

If the product has been exposed to rain or water. 

 

15.

 

Adjust only those controls that are covered by the operating instructions.  Improper adjustments of other 
controls may result in damage to the instrument and will often require extensive work by a technician to 
restore the unit to normal operation. 
 
 
 

digital-micrometer-ld3581-49-86-m44.pdf   3

digital-micrometer-ld3581-49-86-m44.pdf   3

15-6-2020   14:37:59

15-6-2020   14:37:59

Summary of Contents for 49-85

Page 1: ...NES INC The Finest Test Equipment for all Industries 49 85 86 87 MICROMETERS PLEASE READ BEFORE OPERATING UNIT digital micrometer ld3581 49 86 m44 pdf 1 digital micrometer ld3581 49 86 m44 pdf 1 15 6...

Page 2: ...y through Friday from 8 30 AM to 5 00 PM EST TMI also offers on site Preventative Maintenance and Calibration service Please take the time to fill out the postage paid Warranty Card completely and ret...

Page 3: ...ting of 600v 10 Do not remove any panels from the tester Never push objects of any kind into any openings in the instrument s covers Failure to heed this warning could result in fire or electric shock...

Page 4: ...described below are required In case of eye contact Flush the eyes with plenty of clean water for at least 15 minutes immediately without rubbing Take a medical treatment If appropriate procedures ar...

Page 5: ...CALIBRATION GAUGE 7 FEATURES 7 NAME AND FUNCTION OF PARTS 8 SETUP 12 OPERATION 12 INTRODUCTION 16 PARALLELISM CHECK ADJUSTMENT 16 STATISTICS 15 SERIAL DATA OUTPUT 15 MAINTENANCE 18 digital micrometer...

Page 6: ...well as a movable pressure foot is made from lapped stainless steel APPLICATION The TMI Micrometer is designed to measure the thickness or caliper of paper sheets films and foils Almost any material...

Page 7: ...unted for CALIBRATON GAUGE To check the calibration properly the user of the micrometer should have the necessary gauge blocks on hand The gauge blocks can be ordered separately from TMI See Section 3...

Page 8: ...00 15 Standard Model 2 pieces of the afore mentioned part number make this weight 6 Lower Anvil A testing surface that is optically flat The specimen is placed on the anvil s surface and when the pres...

Page 9: ...the AC power inlet of the instrument before opening the fuse holder Do not use fuses with a higher current rating then the original as this can cause damage to the instrument The use of repaired fuse...

Page 10: ...49 85 86 87 10 Rev E Figure 1 digital micrometer ld3581 49 86 m44 pdf 10 digital micrometer ld3581 49 86 m44 pdf 10 15 6 2020 14 37 59 15 6 2020 14 37 59...

Page 11: ...49 85 86 87 11 Rev E Figure 2 11 10 13 12 digital micrometer ld3581 49 86 m44 pdf 11 digital micrometer ld3581 49 86 m44 pdf 11 15 6 2020 14 37 59 15 6 2020 14 37 59...

Page 12: ...er plug needs to be adapted to the local power requirements this must be done by a qualified electrical engineer The plug must be equipped with a safety earth terminal Please Note Power cord wire colo...

Page 13: ...hat are kinked bent or creased should not be used since this may affect the reading of the sample 9 Measure the thickness by placing the specimen between the automatically cycling pressure foot and th...

Page 14: ...g is within the tolerance band around zero Zero Threshold This sets a small range around a reading of 0 00 to be reported as 0 00 For example if the machine is set to a Zero Threshold of 2 m then any...

Page 15: ...election box iv Pressing UNITS when the RETURN is highlighted will return to the main statistics screen c Press and hold the UNITS key then press the ZERO key to delete all readings User confirmation...

Page 16: ...e steel gauge blocks of different sizes See Section 3 Specifications These gauge blocks are checked against standards that are traceable to the NIST The part number for the TMI gauge blocks is as foll...

Page 17: ...49 85 86 87 17 Rev E Figure 1 digital micrometer ld3581 49 86 m44 pdf 17 digital micrometer ld3581 49 86 m44 pdf 17 15 6 2020 14 38 00 15 6 2020 14 38 00...

Page 18: ...ted recheck the parallelism For instruments 49 86 00 0003 and 49 87 00 0003 perform three sets of readings adjusting the screws each iteration in order to establish a baseline parallelism Only perform...

Page 19: ...ons or order acknowledgements provided All materials delivered services provided and work performed by TMI are subject to the Terms and Conditions listed on the linked document To view and or download...

Page 20: ...digital micrometer ld3581 49 86 m44 pdf 20 digital micrometer ld3581 49 86 m44 pdf 20 15 6 2020 14 38 00 15 6 2020 14 38 00...

Reviews: