background image

3

Variable
Frequency
Drive

Reactor

Reactor

AC Machine

 

 

AC Machine

AC Machine

Variable
Frequency
Drives

Variable
Frequency
Drives

3

XL Drive Family Power Expansion

Higher Power Levels.  

The XL VFDs can be run in 

parallel to produce higher power levels than single 
banks.  Two, three, or four banks can be combined 
to obtain the desired power.  The example below 
shows how an XL VFD can be expanded to four 
banks for a power of 120 MVA (156,000 hp).  The 
table shows the maximum power levels available 
from the VFD family.

The multi-bank VFDs provide drive and control 
redundancy for improved reliability.  

• 

Synchronous or Induction motor can control 
rotating machinery directly for low and high 
speed applications.

• 

A redundant control cabinet signifi cantly 
enhances reliability.  

• 

Synchronous motor can control rotating 
machinery directly for low and high speed 
applications; paralleling reactor feeds the motor

• 

A redundant control cabinet signifi cantly 
enhances reliability.  

• 

Synchronous motor can control rotating 
machinery directly for low and high speed 
applications ; paralleling reactor feeds the motor

• 

One bank can be redundant to other three banks 
for increased reliability.

One-Bank TMdrive-XL – Power level up to 30 MVA

Two-Bank TMdrive-XL – Power level up to 60 MVA

Four-Bank TMdrive-XL – Power level up to 120 MVA

XL Drive Power Levels, Single Bank 

Multiple Banks, Max

TMdrive-XL85  30 MVA (39,000 hp) 

120 MVA (156,000 hp)

TMdrive-XL75  20 MVA (26,000 hp) 

80 MVA (104,000 hp)

TMdrive-XL80  15 MVA (19,500 hp) 

30 MVA (39,000 hp)

TMdrive-XL55  8 MVA (10,400 hp) 

16 MVA (20,800 hp)

XLdrive Series Family Application Guide.indd   3

10/3/2011   3:15:55 PM

Summary of Contents for TMdrive-XL Series

Page 1: ...power generation solar inverters oil gas testing mining cranes cement metals TMdrive XL Series Family Product Application Guide TMdrive XL Series Family Product Application Guide...

Page 2: ...the gearbox resulting in increased system efficiency Up to 7 2 kV supply to the motor with no output transformer required Ability to operate drive banks in parallel for higher power levels up to 120 M...

Page 3: ...and high speed applications A redundant control cabinet signi cantly enhances reliability Synchronous motor can control rotating machinery directly for low and high speed applications paralleling rea...

Page 4: ...Bottom or top Clean Motor Output Wave As a result of the five level PWM control the output current waveform is close to a sine wave Harmonic currents in the motor windings are minimized so the heat lo...

Page 5: ...s close to a sine wave Harmonic currents in the motor windings are minimized so the heat loss is negligible and there is very little torque ripple on the output shaft Line to Line Voltage at 100 Speed...

Page 6: ...ne wave Harmonic currents in the motor windings are minimized so the heat loss is negligible and there is very little torque ripple on the output shaft Line to Line Voltage at 100 Speed U phase Curren...

Page 7: ...s is negligible and there is very little torque ripple on the output shaft Protective Functions Include Inverter overcurrent Inverter overvoltage Low system voltage Motor ground fault Motor overload C...

Page 8: ...ochure is provided free of charge and without obligation to the reader or to TMEIC TMEIC Corporation does not accept nor imply the acceptance of any liability with regard to the use of the information...

Reviews: