background image

7

Power Input/Output

Converter

•  AC-fed 12- or 24-pulse diode rectifier using externally 

mounted phase shifted transformer; no harmonic filter 
required to meet IEEE 519 guidelines

•  DC bus voltage:  3 x 5,700 Vdc
•  Power factor greater than 95% in speed control range

Inverter

•  Three-level inverter for motor friendly wave form
•  Uses 4 GCT devices for each of three phases
•  3.8 kV output to motor – no output transformer 

required

•  Inverter power modules water cooled
•  Conservative design for expected 20 year MTBF

Input Voltage

Any utility voltage using 
separate transformer input

50/60 Hz ±10%

Output Voltage

3,800 Vac

Output Current

2400 A rms

Output Frequency

50-60 Hz

Output Chopping

600 Hz (max)

Drive Effi ciency

98%

Cable Entry

Top or bottom access

A Clean Output Wave

As a result of the three-level PWM control, the output 
current waveform is close to a sine wave.  Harmonic 
currents in the motor are minimized so the heat loss is 
negligible and there is very little torque ripple on the 
output shaft.

Protective Functions Include

• Inverter overcurrent
• Inverter overvoltage
•  Low system voltage
•  Motor ground fault
• Motor overload
• Cooling fan abnormal
• Over-temperature

• CPU error
•  Water cooling alarm
• Exciter fault
•  DC voltage drop
• Motor inverse rotation
• Stall detection 
• Ground detection

Frequency Control

• Volt/Hertz Control 
• Vector control
•  Power factor control for synchronous motors

Output Voltage  Modulation

The output switching modulation strategy is dynamically 
adjusted based on three speed zones to minimize motor 
torque pulsation.

Drive Inputs

•  LAN Interface Options:  Profibus-DP, DeviceNet, 

Modbus RTU, TOSLINE S-20

•  Input/Output:  6 Analog I/O, 8 Digital I/O

Power Circuits

Motor Control

Gate Commutated Thyristor 
(GCT) with driver board.  
Rated 6,000 Volts, 6,000 
Amps - the world’s largest 
switching device.

TMdrive-XL80 – 15 MVA Frame

Power Rating:

 

15 MVA, expandable to 30 MVA

Output Voltage:

 3.8 

kV

Output Frequency:

 

Rated 50-60 Hz, 50 to 200 Hertz 
option with derate above 100 Hz

Dimensions

Width 4.8 m; Height:  2.7 m

Motor type:

 

Synchronous or Induction

XLdrive Series Family Application Guide.indd   7

10/3/2011   3:16:15 PM

Summary of Contents for TMdrive-XL Series

Page 1: ...power generation solar inverters oil gas testing mining cranes cement metals TMdrive XL Series Family Product Application Guide TMdrive XL Series Family Product Application Guide...

Page 2: ...the gearbox resulting in increased system efficiency Up to 7 2 kV supply to the motor with no output transformer required Ability to operate drive banks in parallel for higher power levels up to 120 M...

Page 3: ...and high speed applications A redundant control cabinet signi cantly enhances reliability Synchronous motor can control rotating machinery directly for low and high speed applications paralleling rea...

Page 4: ...Bottom or top Clean Motor Output Wave As a result of the five level PWM control the output current waveform is close to a sine wave Harmonic currents in the motor windings are minimized so the heat lo...

Page 5: ...s close to a sine wave Harmonic currents in the motor windings are minimized so the heat loss is negligible and there is very little torque ripple on the output shaft Line to Line Voltage at 100 Speed...

Page 6: ...ne wave Harmonic currents in the motor windings are minimized so the heat loss is negligible and there is very little torque ripple on the output shaft Line to Line Voltage at 100 Speed U phase Curren...

Page 7: ...s is negligible and there is very little torque ripple on the output shaft Protective Functions Include Inverter overcurrent Inverter overvoltage Low system voltage Motor ground fault Motor overload C...

Page 8: ...ochure is provided free of charge and without obligation to the reader or to TMEIC TMEIC Corporation does not accept nor imply the acceptance of any liability with regard to the use of the information...