ProPlex Opto-Splitter user manual v1.2.7, 080619
- 9 -
2. Operation
O
PERATING
M
ODES
(RDM)
The Opto-Splitter 2x8 RDM and 2x10 RDM have two modes: DMX, and DMX with RDM. Modes can be
switched using the toggle switch located on the front panel.
Note – The Opto-Splitter Mini RDM always has RDM enabled.
Switch is set to
DMX
Switch is set to
DMX with RDM
A
SSIGNING
I
NPUTS TO
O
UTPUTS
The 2x8, 2x8 RDM, and 2x10 Opto-Splitter outputs can be connected to one of two inputs using the
switches located to the right of each output connector.
connected to connected to
DMX input (A) DMX input (B)