ProPlex Opto-Splitter user manual v1.2.7, 080619    

 

 

   

- 4 -

 

  Never disconnect power cord by pulling or tugging on the cord. 

 
Caution! There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, please 
contact your distributor. 
 

 

 
 

 
F

USE 

R

EPLACEMENT

 

 

The ProPlex Opto-Splitter 2x10 RDM uses a 2.0A, 250V barrel fuse, 5x20mm (0.2x0.8 in.). The 
ProPlex Opto-Splitter 2x8, Opto-Splitter 2x8 RDM, Opto-Splitter Mini, and Opto-Splitter Mini RDM, use 
a 1.0A 250V barrel fuse, 5x20mm (0.2x0.8 in.). 
To replace fuse: 

1.  With a screwdriver turn the fuse cap counter-clockwise to remove fuse cap with fuse. 
2.  Replace fuse attached to fuse cap. 
3.  Reinsert fuse cap with new fuse and tighten clockwise. 

 

 

M

OUNTING

/R

IGGING 

 

P

RO

P

LEX 

M

INI 

E

NCLOSURES

 

 

Orientation – 

ProPlex Mini units may be mounted in any position, using the standard 

yoke. Always make sure there is adequate room for ventilation.  

 

 
Rigging – 

Always consult a certified rigging specialist before suspending any device 

overhead.

 

 

 

Use ProBurger

®

 couplers or equivalent C- or O-type clamps for attaching to truss. After 

establishing the desired position, tighten all appropriate bolts.  

 

 

Always use safety cables! 

  When selecting installation location, consider routine maintenance. 

  Never mount Mini enclosure where it will be exposed to moisture, high humidity, 

extreme temperatures, or restricted ventilation. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Disconnect the power cord before replacing a 
fuse and always replace with the appropriate 
fuse. 

 

Summary of Contents for ProPlex Opto-Splitter 2x10 RDM

Page 1: ...TECHNICAL SERVICES FOR EVENTS THEATRE MUSIC EXHIBITION FILM TV 01483 757211 HIRE STORMLTD CO UK WWW STORMLTD CO UK...

Page 2: ...Opto Splitters USER MANUAL TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com...

Page 3: ...CEMENT 4 PANELS FRONT BACK 5 RDM DMX SERIAL LINK 7 INPUT OUTPUT CONNECTIONS 8 2 OPERATION 9 OPERATION MODES RDM 9 ASSIGNING INPUTS TO OUTPUTS 9 LED INDICATORS 10 FRONT PANEL LED INDICATORS 10 REAR PAN...

Page 4: ...e the line voltage is within the range of accepted voltages This unit accommodates 100 240VAC 50 60Hz All units must be powered directly from a switched circuit and cannot be operated with a rheostat...

Page 5: ...cap with fuse 2 Replace fuse attached to fuse cap 3 Reinsert fuse cap with new fuse and tighten clockwise MOUNTING RIGGING PROPLEX MINI ENCLOSURES Orientation ProPlex Mini units may be mounted in any...

Page 6: ...ProPlex Opto Splitter user manual v1 2 7 080619 5 PANELS FRONT AND BACK Opto Splitter 2x10 RDM...

Page 7: ...ProPlex Opto Splitter user manual v1 2 7 080619 6 Opto Splitter 2x8 RDM Opto Splitter 2x8 Opto Splitter Mini RDM Opto Splitter Mini...

Page 8: ...he female output 5 pin connector of the lighting console 2 Connect the end of the cable coming from the lighting console which will have a female 5 pin connector to the input connector of the DMX Spli...

Page 9: ...les Example 1 RDM DMX Splitter input output connection scheme 10 0 One of the DMX inputs is connected to all of DMX outputs but a second DMX input is not used i e not connect to any of the DMX outputs...

Page 10: ...ng the toggle switch located on the front panel Note The Opto Splitter Mini RDM always has RDM enabled Switch is set to DMX Switch is set to DMX with RDM ASSIGNING INPUTS TO OUTPUTS The 2x8 2x8 RDM an...

Page 11: ...all devices support RDM Some DMX receiving chips are not able to process an RDM signal casuing the device to behave erratically If a problem occurs contact your device manufacturer OPTO SPLITTER 2X8...

Page 12: ...ere are two positions On Terminator is activated Off Terminator is deactivated Activate the DMX terminator if you want to stop data reflections Note Only available on Opto Splitter 2x10 RDM Data The D...

Page 13: ...dise Authorization RMA Number must be obtained from TMB prior to return of any defective merchandise for warranty or non warranty repair For all repairs please contact TMB Tech Support Repair using th...

Page 14: ...ProPlex Opto Splitter user manual v1 2 7 080619 13 PROPLEX OPTO SPLITTERS TECHNICAL SPECIFICATIONS...

Reviews: