1. Introduction 

 

P

RODUCT 

O

VERVIEW 

 

 
The ProPlex Opto-Splitter is range is designed for standard DMX-512 signal amplification, regeneration, and 
splitting to multiple outputs. Just a few of the features include: 

 

  Full RDM functionality. RDM defeat switch on each input (Opto-Splitter 2x8 and Mini non-RDM 

excluded). 

  Shock-mounted circuitry. Designed for extreme conditions and temperatures.  

  Neutrik

 connectors: Locking PowerCon mains and XLR 

  Automatic bit clocking DMX regeneration with less than 1ms lag 

  Outputs switchable between two inputs with LED indicators available on all 2x8 and 2x10 models 

 

U

NPACKING 

I

NSTRUCTIONS

 

 

Upon receipt of the unit, carefully unpack the carton and check the contents to ensure that all parts are 
present and in good condition. Notify the shipper immediately and retain packing material for inspection if 
any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling. Save the 
carton and all packing materials. In the event that a unit must be returned to the factory, it is important that it 
be returned in the original factory box and packing. 

 

P

OWER 

R

EQUIREMENTS

 

 

Before powering the unit, make sure the line voltage is within the range of accepted voltages. This unit 
accommodates 100-240VAC, 50/60Hz. All units must be powered directly from a switched circuit and cannot 
be operated with a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is 
used solely for a 0-100% switch.

 

 
S

AFETY 

I

NSTRUCTIONS

 

 
 

 
 
 

 

 

  Keep this User Guide for future reference. If unit is sold to another user, make sure they also receive this 

instruction booklet. 

  Ensure the unit is connected to proper voltage, and that line voltage is not higher than that stated on the 

device. 

  Make sure there are no flammable materials close to the unit while operating. 

  Always disconnect from the power source before servicing or fuse replacement. Always use the fuse 

specified in this manual.. 

  Always use a safety cable when hanging unit overhead. 

  Maximum ambient temperature (Ta) is 40°C (104°F). Do not operate unit at temperatures above this 

rating.  

  In the event of a serious operating problem, stop using the unit immediately. Repairs must be carried out 

by trained, authroized personnel. Conact the nearest authorized technical assistance center.  Only OEM 
spare parts should be used. 

  Do not connect the device to a dimmer pack. 

  Make sure power cord is never crimped or damaged. 

Please read these instructions carefully. This user guide 
contains important information about the installation, usage 
and maintenance of this product.

 

 

Summary of Contents for ProPlex Opto-Splitter 2x10 RDM

Page 1: ...TECHNICAL SERVICES FOR EVENTS THEATRE MUSIC EXHIBITION FILM TV 01483 757211 HIRE STORMLTD CO UK WWW STORMLTD CO UK...

Page 2: ...Opto Splitters USER MANUAL TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com...

Page 3: ...CEMENT 4 PANELS FRONT BACK 5 RDM DMX SERIAL LINK 7 INPUT OUTPUT CONNECTIONS 8 2 OPERATION 9 OPERATION MODES RDM 9 ASSIGNING INPUTS TO OUTPUTS 9 LED INDICATORS 10 FRONT PANEL LED INDICATORS 10 REAR PAN...

Page 4: ...e the line voltage is within the range of accepted voltages This unit accommodates 100 240VAC 50 60Hz All units must be powered directly from a switched circuit and cannot be operated with a rheostat...

Page 5: ...cap with fuse 2 Replace fuse attached to fuse cap 3 Reinsert fuse cap with new fuse and tighten clockwise MOUNTING RIGGING PROPLEX MINI ENCLOSURES Orientation ProPlex Mini units may be mounted in any...

Page 6: ...ProPlex Opto Splitter user manual v1 2 7 080619 5 PANELS FRONT AND BACK Opto Splitter 2x10 RDM...

Page 7: ...ProPlex Opto Splitter user manual v1 2 7 080619 6 Opto Splitter 2x8 RDM Opto Splitter 2x8 Opto Splitter Mini RDM Opto Splitter Mini...

Page 8: ...he female output 5 pin connector of the lighting console 2 Connect the end of the cable coming from the lighting console which will have a female 5 pin connector to the input connector of the DMX Spli...

Page 9: ...les Example 1 RDM DMX Splitter input output connection scheme 10 0 One of the DMX inputs is connected to all of DMX outputs but a second DMX input is not used i e not connect to any of the DMX outputs...

Page 10: ...ng the toggle switch located on the front panel Note The Opto Splitter Mini RDM always has RDM enabled Switch is set to DMX Switch is set to DMX with RDM ASSIGNING INPUTS TO OUTPUTS The 2x8 2x8 RDM an...

Page 11: ...all devices support RDM Some DMX receiving chips are not able to process an RDM signal casuing the device to behave erratically If a problem occurs contact your device manufacturer OPTO SPLITTER 2X8...

Page 12: ...ere are two positions On Terminator is activated Off Terminator is deactivated Activate the DMX terminator if you want to stop data reflections Note Only available on Opto Splitter 2x10 RDM Data The D...

Page 13: ...dise Authorization RMA Number must be obtained from TMB prior to return of any defective merchandise for warranty or non warranty repair For all repairs please contact TMB Tech Support Repair using th...

Page 14: ...ProPlex Opto Splitter user manual v1 2 7 080619 13 PROPLEX OPTO SPLITTERS TECHNICAL SPECIFICATIONS...

Reviews: