TM INDUCTION HEATING
9
ST PRO 2.3 |
Should an error occur during the heating process, the induction heater will
automatically stop. The corresponding error will be displayed on screen.
In the case of user error, the display indicates what steps are to be taken
to correct the problem. More information about the types of errors can be
found in chapter 7 -
ERRORS
.
An induction heater produces an electromagnetic field within a coil to
transfer energy to a workpiece. The table below shows values of the flux
density in microTesla (µT). These measurements can be used as a guide
conforming to local regulations regarding
the maximum time exposure to magnetic
fields. Different configurations may give
different values. It is impossible to provide
values for all combinations as the variety
of bearing types in combination with the
different yokes is large.
Total 50Hz RMS field for magnetic measurement results. Max. magnetic
flux in safe exposure area, according to the German BG 11 Regulations
is 423
µT.
SAFETY
FEATURES
MP1x
454
864
868
MP2x
189
272
370
MP3x
51
143
201
MP1y
458
874
983
MP2y
191
314
416
MP3y
80
156
196
Measurement position (cm)
B-field
total
(µT)
MP2x
60
MP1x
30
MP3x
90
30
60
90
MP1y
MP2y
MP3y
X
(cm)
Y
(cm)