EF200W-C
38
Used in combination with flanges according to DIN EN 1092-1: PN 16
1.4404 (316, 316L)
DN
[mm]
Centering diameter
[mm]
D1
1)
/ D2
2)
s
[mm]
15
54.3
D2
2.0
25
74.3
D1
3.5
40
95.3
D1
5.3
50
110.0
D2
6.8
80
145.3
D2
10.1
100
165.3
D2
13.3
150
221.0
D2
20.0
1)
The flow conditioner is fitted at the outer diameter between the bolts.
2)
The flow conditioner is fitted at the indentations between the bolts.
Used in combination with flanges according to DIN EN 1092-1: PN 25
1.4404 (316, 316L)
DN
[mm]
Centering diameter
[mm]
D1
1)
/ D2
2)
s
[mm]
15
54.3
D2
2.0
25
74.3
D1
3.5
40
95.3
D1
5.3
50
110.0
D2
6.8
80
145.3
D2
10.1
100
171.3
D1
13.3
150
227.0
D2
20.0
1)
The flow conditioner is fitted at the outer diameter between the bolts.
2)
The flow conditioner is fitted at the indentations between the bolts.
Used in combination with flanges according to DIN EN 1092-1: PN 40
1.4404 (316, 316L)
DN
[mm]
Centering diameter
[mm]
D1
1)
/ D2
2)
s
[mm]
15
54.3
D2
2.0
25
74.3
D1
3.5
40
95.3
D1
5.3
50
110.0
D2
6.8
80
145.3
D2
10.1
100
171.3
D1
13.3
150
227.0
D2
20.0
1)
The flow conditioner is fitted at the outer diameter between the bolts.
2)