background image

 

172-65116M-02 (CP-N)  16 Jun 2011

 

18

 

Maintenance and Part Replacement 

 

 

Use hoisting equipment for heavy objects (weighing approximately 

20 kg or more). Failure to do so may result in back strain or other injury if 

the object should fall. 

CAUTION 

 

 

NEVER apply direct heat to the float. The float may explode due to 

increased internal pressure, causing accidents leading to serious injury 

or damage to property and equipment.

 

WARNING 

 

 

 

When disassembling or removing the product, wait until the internal 

pressure equals atmospheric pressure and the surface of the product 

has cooled to room temperature. Disassembling or removing the 

product when it is hot or under pressure may lead to discharge of fluids, 

causing burns, other injuries or damage.

 

CAUTION 

 

 

 

Be sure to use only the recommended components when repairing the 

product, and NEVER attempt to modify the product in any way. Failure to 

observe these precautions may result in damage to the product or burns 

or other injury due to malfunction or the discharge of fluids.

 

CAUTION 

 

 

Make sure the power supply is OFF before carrying out work on the 

wiring or inspections involving disassembly. If such work is carried out 

with the power on, there is a danger that equipment may malfunction or 

electric shock may occur, leading to injury or other accidents. 

CAUTION 

 

 

Make sure that wiring work requiring a special license is carried out only 

by qualified personnel. If carried out by unqualified personnel, 

overheating or short circuits leading to injury, fires, damage or other 

accidents may occur. 

CAUTION 

 

 

When using this product, NEVER stand close to, or leave tools anywhere 

near, moving parts, such as the shaft. Contact with moving parts or 

objects becoming caught in moving parts could lead to injury or 

damage or other accidents. 

CAUTION 

 

Installation, inspection, maintenance, repairs, disassembly, adjustment and valve 
opening/closing should be carried out only by trained maintenance personnel. 
 

Replaceable parts 

Refer to the instruction manual for the pump unit. 
On maintenance inspection, alignment of the pump and motor should be checked. The 
alignment should be within 5/100 mm axially and radially at the coupling. 
 

Pump unit maintenance 

Pump unit maintenance including Bearing, Shaft Seal, Coupling, and Lubricant must be 
done according to the pump unit manual. 

Summary of Contents for CP-N

Page 1: ...172 65116M 02 CP N 16 June 2011 Condensate Recovery Pump CP N Copyright 2011 by TLV CO LTD All rights reserved ISO 9001 ISO 14001...

Page 2: ...r 8 Cooling of shaft seal 8 Lubrication 8 Operation 9 Checks before startup 9 Water quality 9 Standard piping diagram 10 Preparation before test run 12 Valve operation for piping blowdown before test...

Page 3: ...It combines a centrifugal or multi stage turbine pump for hot water and an ejector delivering condensate continuously at a high pressure It contributes to energy conservation to a great extent due to...

Page 4: ...at of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage Install...

Page 5: ...mbly If such work is carried out with the power on there is a danger that equipment may malfunction or electric shock may occur leading to injury or other accidents Make sure that wiring work requirin...

Page 6: ...jet and pump out force of condensate 2 Ejector Mixes the pressurized condensate with the flow in condensate giving the required NPSH req to the pump 3 Delivery pressure regulating valve Maintains the...

Page 7: ...arts such as the shaft Contact with moving parts or objects becoming caught in moving parts could lead to injury or damage or other accidents CAUTION Pump installation Installation inspection maintena...

Page 8: ...f cross sectional area 5 Install a riser pipe of at least 1 m at the pump suction side excluding the liquid vapor separator header 6 Install a pressure gauge at the condensate header 7 Install a gate...

Page 9: ...e with help of the tally marks punched on the coupling flanges 5 After the pump reaches the rated temperature check the alignment again Fig A Cooling of shaft seal The shaft seal should be cooled when...

Page 10: ...Valves pressure gauges and check valves should be installed at the correct positions 7 The piping should be just as shown in the system piping layout The pipes should be flushed 8 The strainer in the...

Page 11: ...V 8 T 2 FS FM V 11 V 16 V 12 C 1 F 2 V 10 V 15 V 14 C 2 V 14 M B 3 M B m V n C m V o V m V m V g C n V p V 13 P 1 H V 1 V 2 V 3 V 4 m P Feed water tank Feed water tank Boiler Feed water Cooling water...

Page 12: ...en V13 Flowmeter outlet valve Open V14 Inlet and outlet valves for MB3 Open V15 Bypass valve for MB3 Close V16 Bypass valve for MBm Close Vm Inlet and outlet valves for MBm Open Vn Initial blow valve...

Page 13: ...nsion of pipes Pipe support A Supports the pump inlet pipe and absorbs vibration Pipe support B Supports the pump outlet pipe and absorbs vibration M1 Filling detector Senses whether the pump is fille...

Page 14: ...s required to remove dirt scale and oil which are inevitably present in pipes during construction Flushing should be continued till the condensate contains no foreign matter Valve operation for flushi...

Page 15: ...l from the thermostat TS to reject the condensate When the condensate temperature rises MB1 closes allowing the condensate to flow into the pump 5 The valve MB2 is in the open position by the signal f...

Page 16: ...2 P2S 2 8 Feed the condensate into the boiler automatically To do this put the select switch for feed water control to the automatic position M B3 M Bm VO Vn V10 V12 V13 V11 V14 FM Symbol Operation Sy...

Page 17: ...erify that the pump slows down smoothly and stops quietly 3 If freeze up is expected blow condensate using a valve at the bottom of the pump Also blow the cooling water line 4 Emergency Stop the pump...

Page 18: ...e press reg valve clockwise to raise the set pressure and reduce the pump delivery Repeated start and stop Wrong setting or failure of control system Change the set value of the pressure switch or inv...

Page 19: ...y is OFF before carrying out work on the wiring or inspections involving disassembly If such work is carried out with the power on there is a danger that equipment may malfunction or electric shock ma...

Page 20: ...tion use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or inadequate insp...

Reviews: