Radon VAC

TM

Side Wall Radon Mitigation System 

READ OWNERS INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION.

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT. DO NOT DESTROY.

Model RMS160

DESCRIPTION

The Radon Vac

TM

Radon Mitigation System is designed to reduce radon levels in homes by removing radon gas from

beneath the home and discharging it to the outdoors. The Radon Vac

TM

eliminates intrusive PVC pipe runs vertically through

living areas or ugly PVC runs up the home exterior. It reduces radon across a variety of sub-slab soil types (dirt, gravel,
etc.). It features a sealed, galvanized housing & PSC permanently lubricated, quiet-low watt motor. The corrosion-proof,
Variable Aspiration Control Hood dilutes radon gas with infused outdoor air & propels it away. Airflow velocity easily adjusts
for various pipe lengths and extraction point from a sump pit or below basement floor.

PERFORMANCE & SPECIFICATIONS

RMS160 Performance

MODEL RMS160

Motor:   115 Volts ~ 50/60 Hz
Watts: 50
Amps: 0.80 maximum

©2011 TJERNLUND PRODUCTS, INC.  ALL RIGHTS RESERVED

P/N: 8504183  

Summary of Contents for rms160

Page 1: ...the outdoors The Radon VacTM eliminates intrusive PVC pipe runs vertically through living areas or ugly PVC runs up the home exterior It reduces radon across a variety of sub slab soil types dirt grav...

Page 2: ...ctric shock or personal injury To reduce these risks significantly use this unit only in the manner intended by the manufacturer If you have questions contact Tjernlund Products Always disconnect the...

Page 3: ...Seal PVC pipe penetration around top of slab sump pit or vapor barrier For sub slab penetrations provide 5 10 gallons of pea gravel under the slab to improve the air path area to the pipe Avoid struc...

Page 4: ...ontally from any door or window The bottom of the discharge should be located at least 12 inches above grade If possible do not locate discharge on a wall that faces the direction of the prevailing wi...

Page 5: ...after performing the inflation test required for adjustment of the VAC termination hood 7 Connect PVC from the slab or sump pit to the inlet of the fan Glue each section with adhesive approved for you...

Page 6: ...t 12 After time test assemble discharge hood by sliding the included PVC Flange onto the studs of the discharge hood and secure with included nuts Note that either set of 4 round holes on the flange c...

Page 7: ...airing or replacing at our option any product which shall within the above stated war ranty period be returned to Tjernlund Products Inc at the address listed below postage prepaid If claim is filed w...

Reviews: