RMS160 FAN DIMENSIONS

RMS160 HOOD DIMENSIONS

GENERAL INFORMATION

Each Radon VAC

TM

is factory line tested before shipment. After opening carton, inspect thoroughly for shipment damage.

Fan should rotate freely and all electrical wires and connections should be secured.  If any damage is found, notify freight
carrier and your distributor immediately and file a concealed damage claim.

INSTALLATION GUIDELINES 

The RMS160 must be installed by a qualified installer in accordance with these instructions and all local codes or in their
absence in accordance with the latest editions of the International Residential Code and International Electrical Code.
Improper installation can create a hazardous condition such as fire, electric shock or personal injury. To reduce these risks
significantly, use this unit only in the manner intended by the manufacturer. If you have questions, contact Tjernlund
Products. Always disconnect the RMS160 from its power source before installation and servicing.

CAUTION: 

For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. No main-

tenance is required for the RMS160, but regular radon testing is recommended to verify levels remain low.

WARNING:

To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. Do not

plug in fan without PVC attached in order to avoid contact with rotating blower wheel.

The Radon VAC

TM

radon mitigation system is an important part of limiting the entry of radon gas into your home. However,

minimizing your home's exposure to radon requires a comprehensive approach and includes, but is not limited to:

Summary of Contents for rms160

Page 1: ...the outdoors The Radon VacTM eliminates intrusive PVC pipe runs vertically through living areas or ugly PVC runs up the home exterior It reduces radon across a variety of sub slab soil types dirt grav...

Page 2: ...ctric shock or personal injury To reduce these risks significantly use this unit only in the manner intended by the manufacturer If you have questions contact Tjernlund Products Always disconnect the...

Page 3: ...Seal PVC pipe penetration around top of slab sump pit or vapor barrier For sub slab penetrations provide 5 10 gallons of pea gravel under the slab to improve the air path area to the pipe Avoid struc...

Page 4: ...ontally from any door or window The bottom of the discharge should be located at least 12 inches above grade If possible do not locate discharge on a wall that faces the direction of the prevailing wi...

Page 5: ...after performing the inflation test required for adjustment of the VAC termination hood 7 Connect PVC from the slab or sump pit to the inlet of the fan Glue each section with adhesive approved for you...

Page 6: ...t 12 After time test assemble discharge hood by sliding the included PVC Flange onto the studs of the discharge hood and secure with included nuts Note that either set of 4 round holes on the flange c...

Page 7: ...airing or replacing at our option any product which shall within the above stated war ranty period be returned to Tjernlund Products Inc at the address listed below postage prepaid If claim is filed w...

Reviews: