background image

WIRING

T-STAT

CB14 TEMPERATURE OR TIMER SWITCH CONTROLLED

FIGURE 8089021   6-10-13

GREEN

N

L1

WHITE

TIMER SWITCH

10 MIN

20 MIN

30 MIN

60 MIN

OFF

BLACK

WHITE

GREEN

RED

RED

RED

BLACK

T-STAT

CB14 TEMPERATURE OR SWITCH-IT CONTROLLED

FIGURE 8089025   6-13-13

GREEN

RED

RED

WHITE

BLACK

N

L1

REMOTE

OFF

ON

RED

SMOOTH BLACK

RED

BLACK

RIBBED

ANTENNA

TO MOTOR

STRETCHED VIEW

SWITCH-IT

WIRELESS RECEIVER

T-STAT

CB14 SWITCH-IT CONTROLLED

FIGURE 8089024   6-13-13

GREEN

RED

RED

WHITE

BLACK

N

L1

REMOTE

OFF

ON

RED

SMOOTH BLACK

RED

BLACK

RIBBED

ANTENNA

TO MOTOR

STRETCHED VIEW

SWITCH-IT

WIRELESS RECEIVER

T-STAT

CB14 TEMPERATURE AND MANUALLY CONTROLLED

FIGURE 8089023   6-17-13

GREEN

N

L1

WHITE

WALL SWITCH

RED

RED

BLACK

Summary of Contents for Cool Breeze CB14

Page 1: ...e is found notify freight carrier and your distributor immediately and file a concealed damage claim OPERATION The CB14 can be wired to be controlled manually by a wall switch not included by the included temperature switch or both Also available from Tjernlund are wall mount timers P N 950 9300 and wireless wall switches P N SWS Contact Tjernlund for more information on these controls INSTALLATIO...

Page 2: ... paths to gable ridge or roof vents 1 Outline a 16 x16 square on your garage ceiling at the desired fan location considering the above points 2 Cut along outline with drywall knife to create hole opening Figure A 3 Intake plenum can be pushed up into the hole and secured from the garage Figure B or placed on ceiling from attic and secured from above Figure C Center the intake plenum along opening ...

Page 3: ...m Secure both mounting bracket ends to the truss or joist Repeat on the other side of the intake plenum 4 Manually insert crimped end of fan into the radiation damper Drill 1 8 holes through both the radiation damper and fan on the 4 sides of the fan assembly damper and fan Figure G Secure the radiation damper to the fan using the 4 included screws Figure H 5 Place fan assembly damper and fan onto...

Page 4: ...ATURE MAKE 130 75 85 95 105 115 125 135 65 65 SMALLER RANGE TOWARDS LOW LARGER TEMPERATURE RANGE TOWARDS THE HIGH END END TJERNLUND LIMITED ONE YEAR WARRANTY Tjernlund Products Inc warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of 1 year from the date of original purchase or delivery to the original p...

Page 5: ...6 10 13 GREEN N L1 RED RED WHITE BLACK TIMER SWITCH 10 MIN 20 MIN 30 MIN 60 MIN OFF BLACK WHITE GREEN RED T STAT BLACK WHITE CB14 TEMPERATURE CONTROLLED FIGURE 8089018 6 5 13 GREEN RED RED WHITE GREEN RED N L1 T STAT CB14 CONTROLLED BY ANY SWITCH FIGURE 8089019 6 17 13 GREEN N L1 RED RED WHITE BLACK SWITCH MUST BE RATED TO 5 AMPS 115 VAC ...

Page 6: ...3 GREEN RED RED WHITE BLACK N L1 REMOTE OFF ON RED SMOOTH BLACK RED BLACK RIBBED ANTENNA TO MOTOR STRETCHED VIEW SWITCH IT WIRELESS RECEIVER T STAT CB14 SWITCH IT CONTROLLED FIGURE 8089024 6 13 13 GREEN RED RED WHITE BLACK N L1 REMOTE OFF ON RED SMOOTH BLACK RED BLACK RIBBED ANTENNA TO MOTOR STRETCHED VIEW SWITCH IT WIRELESS RECEIVER T STAT CB14 TEMPERATURE AND MANUALLY CONTROLLED FIGURE 8089023 6...

Reviews: