TABLE OF CONTENTS
PAGE(S)
VSUB BLOWER DESCRIPTION ................................................................................................................................. 1
DIMENSIONS AND SPECIFICATIONS ........................................................................................................................ 1
VSUB FAN PERFORMANCE CURVES..........................................................................................................................2
INSTALLATION RESTRICTIONS & CAUTIONS ........................................................................................................... 3
ADDITIONAL REQUIREMENTS BASED ON DRAFT INDUCER OR COMBUSTION AIR APPLICATION ............... 3-4
DRAFT INDUCER TERMINATION CLEARANCES FOR CANADIAN & U.S. INSTALLATIONS ............................... 4-6
COMBUSTION AIR INTAKE CLEARANCES ................................................................................................................ 6
COMBUSTION AIR INTAKE HOOD/LOUVER OPENING SIZING............................................................................. 6-7
VSUB INSTALLATION ............................................................................................................................................... 7-8
PSA-1 FAN PROVING SWITCH INSTALLATION ...................................................................................................... 8-9
WIRING .....................................................................................................................................................................9-11
PSA-1 SAFETY INTERLOCK AND DRAFT ADJUSTMENT SET-UP PROCEDURE..............................................12-13
SAFETY INTERLOCK TEST.........................................................................................................................................13
COMBUSTION AIR ...................................................................................................................................................... 13
MAINTENANCE, SERVICE & HOUSING ROTATION .............................................................................................13-14
HOW TO OBTAIN SERVICE & LIMITED WARRANTY ..........................................................................................14-15
REPLACEMENT PARTS ..............................................................................................................................................15
Tjernlund Products welcomes your comments and questions. Call us at 800-255-4208, Fax 651-426-9547, Email us at
[email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.
VSUB-SERIES UNIVERSAL BLOWER DESCRIPTION
The VSUB-Series Universal Blowers are a multi-purpose adjustable-fixed speed or automatic-variable speed blower. It can vent natur-
al gas, LP-gas and oil fired heating appliances, clothes dryers or be used as a utility blower that will handle up to 575° F. It can also
be used as a adjustable-fixed speed or as an automatic-variable speed combustion air intake blower. All models are supplied with the
model PSA-1 Fan Proving Switch which will disable the burner(s) if an exhaust/supply malfunction should occur, and a FFP-1 fire
/freeze limit that will shut the VSUB Blower off in the event of extreme temperature swings for combustion air applications. The VSUB
Blower is rated for indoor or outdoor installation. Use positive pressure rated vent on the discharge side of the blower when venting
flue gases and mounting indoors. Refer to heating appliance manufacturer's instructions regarding specific venting requirements.
DIMENSIONS AND SPECIFICATIONS
1
3x230/460
2875
1.6
66
7 7/8
5 1/4
16 1/2
28 1/2
14 1/2
10 1/4
2125
3.2
153
11 7/8
9 5/8
21 1/2
33
17 3/8
13
2115
6.0
218
15 7/8
12
27 3/4
42 3/8
23 1/4
16
1760
8.8
319
19 7/8
14 1/2
32 3/4
44 3/4
26 1/2
23 1/4
Yes with
VFD
VSUB8
VSUB12
VSUB16
VSUB20
Does not include Amp load of VFD Drive.
in
in
in
in
in
in
lbs
@ 208 V
VAC
A
C
E
G
I
K
Dimensions
Weight
Full Speed
Max RPM with VFD
Voltage
MODEL
Variable Speed Motor
Figure 8067001 3/3/04
Power Rating
hp
1/3
1
3
2
L
J
H
in
18 1/2
in
in
15 1/2
30 1/2
22
35
18 7/8
F
D
B
in
in
7 7/8
7 5/8
in
10
10
11 7/8
12 1/2
25 1/2
28
46 3/4
26 3/4
24 3/4
44 3/8
14
14
19 3/4
15 7/8
13 1/4
14
M
O
N
8
in
in
in
23 1/2
13 3/8
9
28 1/2
15 1/2
19
43 3/4
23 1/2
15 3/8
34 3/4
18 7/8
3x230/460
3x230/460
3x230/460
@ 460 V
0.8
1.5
2.8
4.1
Yes with
VFD
Yes with
VFD
Yes with
VFD
5.6
@ 230 V
1.5
3.0
8.2
Amps
*
*
O
L
END VIEW
M
N
K
MOUNTING
LOCATION (4)
D
TOP VIEW
B
ØA
ØF
E
C
G
H
I
J
INCLUDED SQUARE
TO ROUND ADAPTER