15
Ducting Connections
Titon recommend the use of guidance given in the Domestic Ventilation
Compliance Guide 2010 Edition ISBN-978 1 85946 378 9 and Approved Document
Part F 2010 ISBN-978 1 85946 370 3 for all installations in the United Kingdom.
The above documents can be downloaded free from www.
planningportal.gov.uk
Once the unit has been installed and the ducting is ready to connect to the unit,
remove the Transport Bungs from the Duct Ports.
Titon recommend that:
1. Ø125mm ducting is used to connect the HRV1.25
Q Plus
.
2. Ø150mm ducting is used to connect the HRV1.75, 2 & 3
Q Plus
.
3. A short piece of flexible ducting, approximately 200mm long is used to
connect the unit to the ducting system.
4. Any flexible ducting used must be pulled taught.
5. A minimum distance of 200mm between the HRV
Q Plus
unit and any sharp
bends in duct work.
ENSURE DUCTING IS CONNECTED TO THE CORRECT PORTS
Extract from dwelling
Supply to dwelling
From atmosphere
To atmosphere
240V. AC
ENSURE DUCTING IS CONNECTED TO
THE CORRECT PORTS
Extract from dwelling
Supply to dwelling
From atmosphere
To atmosphere
front
Summary of Contents for auralite TP518
Page 21: ...21 Wiring Diagrams ...
Page 22: ...22 Notes ...
Page 30: ...30 Service Record Serviced By Company Date Notes ...