29
Configurable Item
Range
Default
Configured
Additional
information
Min
Max
Speed 4,
SUMMERboost®
Supply
14% (72)
100% (392)
100% (392)
Extract
14% (72)
100% (392)
100% (392)
Summer Bypass
Extract
17°C
35°C
25°C
Supply
10°C
20°C
18°C
In order for the Summer Bypass to operate the temperatures of both the air being extracted from the
property and supplied from outside must be above their individual thresholds. If the temperature of the
Supply air is less than 1°C cooler than the Extracted air the Summer Bypass does not operate to prevent
the warmer air being supplied directly to the property.
SUMMERboost®
Enabled
Disabled
Enabled
SUMMERboost® operates in conjunction with Summer Bypass and switches the fans to Speed 4. It can
also be disabled by a latching switch if fitted.
Switch Inputs
SW1
Kitchen Boost
SW2
Wet Room
Boost
SW3
SUMMERboost®
Disable
Switch options are: Kitchen Boost, Wet Room Boost, Speed 1, Speed 4, SUMMERboost disable, OFF
normally open,OFF normally closed, Manual Summer Bypass. When configured as Kitchen or Wet room
Boost, the switch will use the associated Boost overrun and delay times for that room.
Live Switch Inputs
LS1
Kitchen Boost
LS2
Wet Room
Boost
Live Switch options are: Kitchen Boost, Wet Room Boost, Speed 1, Speed 4, SUMMERboost disable, OFF
normally open,OFF normally closed, Manual Summer Bypass. Live Switches also use the Boost overrun
and delay times for the rooms they have been configured to.
auraSMART
®
WiFi
Connection Type
WiFi Direct
Bracketed values refer only to the values displayed by the TP 737 (m³/hr) controller.
Compatibility
The
aura-t
™
SMART
(WiFi) controller is compatible with HRV units software version
FW0027-0206 onwards circa June 2016.