Feature
Standard without
aura-t
Enhanced with
aura-t
connected or integrated
Speed Selection Speed 1, Setback is enabled by
connection of a volt free one-
way switch, or combined with
the Speed 3 Boost with the 3
position switch TP 508.
Speed 3, Boost can be triggered
by any device which provides a
volt free one-way switch, such
as a PIR, thermostat, humidistat
or a standard one-way switch.
As the standard units with the
additional functionality of:
Speeds 1, 3 & 4 can be assigned
to any of the volt free switch
inputs. The unit speed can also
be manually selected via the on
screen 1, 2, 3 & 4 buttons/icons
which are also used to display
any automatically selected
speed.
Summer Bypass Summer Bypass is designed to operate during hot periods where
fresh air can be vented straight into the property without being
preheated by the extracted stale air. Summer Bypass operation is
automatically controlled. The Summer Bypass mechanism diverts
the stale air being extracted from the dwelling around the heat
cell so that its heat energy is not transferred to the fresh air being
supplied to the property.