13
Run Mode
The
aura-t
controls the HRV unit’s 4 programmable speed settings.
This is the Run Mode screen; use the number buttons to select the required fan
speeds. Speeds 1,3 & 4 are on a one hour timer, after the hour has elapsed the HRV
will return to Speed 2.
The current running speed will be indicated by the corresponding number button
being highlighted.
Press and Hold the [1] or [2] button to enable boost Inhibit, the
Padlock icon will display to indicate Boost inhibit is active.
Pressing and Holding either the [1] or [2] button again will disable
Boost Inhibit.
Extract
Supply
Press the supply or extract buttons to cycle between fan speed
and temperature.
With fan speed selected the actual percentage speed of both fans is
displayed.
Selecting temperature displays the temperature of the air being
supplied from the atmosphere and extracted from the property.
Status Icons
If the fan speed is being controlled by an external switch, or sensor this is indicated by
an icon beneath the speed selection buttons being visible.
The icons are as follows:
An external switch is active and is holding the HRV at the indicated
speed. If this icon is flashing along with the Speed 3 button and the
backlight a switch has held the HRV in Boost for more than 2 hours
and Boost Alert is active.