Warnings, Safety Information and Guidance
Important Information
Important: read these instructions fully before the installation of this appliance
1. Installation of the appliance and accessories must be carried out by a qualified and suitable
competent person and be carried out in clean, dry conditions where dust and humidity are
at minimal levels.
2. This manual covers the installation of the Heat Recovery Ventilation (HRV) unit
3. All wiring must conform to current I.E.E. Wiring Regulations and all applicable standards
and Building Regulations.
4. Inspect the appliance and electrical supply cord. If the supply cord is damaged, it must be
replaced by the manufacturer, their service agent or similarly qualified persons in order to
avoid a hazard.
5. The unit is supplied with a mains rated 3 core flexible cord (PVC sheathed, brown, blue and
green/yellow 0.75mm²).
6. The appliance must be connected to a local double pole isolation switch with a contact
separation of at least 3mm.
7. The appliance must be earthed.
8. HRV3 suitable for 230V ~ 50/60Hz single phase with a fuse rating of 5A.
9. Controller - control & communication cable access is via the fitted cable gland(s) which are
suitable for Ø3- 6mm cable.
10. Controller - control & communication cable - Unshielded 4 Core 18-24AWG
Stranded, Tinned Copper.
11. Control & communication cables should not be placed within 50mm or on the same metal
cable tray as any 230V~ lighting or power cables.
12. Ensure all cable glands are fully tightened and supplied grommets are used.
13. The unit must be stored in a clean and dry environment. Do not install the appliance in
areas where the following may be present or occur;
•
Excessive oil or a grease laden atmosphere,
•
Corrosive or flammable gases, liquids or vapours,
•
Ambient temperatures above 40°C or below -5°C,
•
Humidity levels above 90% or is a wet environment.
14. The appliance is not suitable for installation to the exterior of the dwelling.
15. This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children should be supervised to ensure that
they do not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
16. Ensure that external grilles are located away from any flue outlet, in accordance with rel-
evant Building Regulations.
17. The unit must not be connected to a tumble dryer or a cooker hood.
18. Precautions must be taken to avoid the back-flow of gases into the room from an open flue
appliance.
19. Ensure all ducting, condensate drain and associated pipe work is free from debris and
blockages before switching on the unit.
2
Summary of Contents for aura-t TP536/EU
Page 13: ...13 ...
Page 15: ...HRV3 Wiring Diagrams Supply Supply wiring Ref EE167 230V 2 Pole Isolator Fuse 15 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 33: ...33 ...
Page 38: ...Service Record Serviced By Company Date Notes 38 ...