Timer Mode
The controller has a seven day, four events per day timer. The timer is used to automatically change the HRV speed to
Setback, Speed 1 at programmed times.
An additional function of the timer is that when it activates Setback there is an option to engage Boost Inhibit.
This is the Timer Mode screen; the buttons displayed on screen have the following functions:
Tap the Play / Pause button to toggle between play and pause.
Press and Hold to pause timers indefinitely.
The Run arrow indicates the timer is currently active and will be used to switch the HRV in and out of Speed 1
The Pause and Hour Glass symbols indicate the Timer is temporarily paused; Timer will restart 8 hours after being
invoked.
The Pause symbol indicates the timer is currently inactive and will have no effect on fan speeds; this pause is
indefinite.
Timer Setup , Tap this button to adjust the Timer, see Timer Setup section.
Tap this to Exit and return to Run Mode.
When the timer has automatically switched the HRV to Speed 1 this can be manually overridden by
tapping [2-4] keys. Tap the Speed 1 key to return to timer control.
When the next timed event occurs the unit will revert to timer control.
Manual override is not possible if Boost Inhibit is in operation.
26