TITAN INDUSTRIAL shall not be responsible for any consequences resulting from improper use of
this equipment. The operator is required to read the entire contents of this manual before attempt-
ing to operate the unit. If the operator does not completely understand the instructions and all of the
hazards of operating this unit after reading this manual, he/she must call the factory at 1-800-845-4141
to answer these questions to his/her complete satisfaction before proceeding.

READ AND COMPLETELY UNDERSTAND

entire contents of this Owner’s Manual and become familiar with

the unit before attempting to start using this equipment! It is your responsibility to know its applications,
limitations, and hazards! Call the factory at 1-800-845-4141 with any questions.

FOR OUTDOOR USE ONLY!

Never use this unit inside any enclosure including

the generator compartment of a recreation vehicle (RV) or inside any building. No
modifications will eliminate the danger of possible carbon monoxide poisoning,
fire, or explosion.

TWO (2) FEET OF CLEARANCE

on all sides is required even while using outdoors.

This unit is sold solely for the purpose of portable power. Other applications could void warranty.
User accepts responsibility for injuries and/or damage resulting from other applications.

IMPORTANT !

READ FIRST

OWNER’S

MANUAL

MODEL TG 9000ES

Industrial Generator

2

DESCRIPTION

THE TITAN INDUSTRIAL INC. MODEL TG 9000ES

is a

gas engine driven, revolving field, alternating current (AC)
generator designed to supply electrical power for com-
patible electrical tools, motors, appliances, and lighting
(see wattage reference guide on page 9).

The Model TG 9000ES operates at 120 volt and/or 240
volt, single phase, 60 Hz and will operate devices that
require up to 7200 watts continuous and 8400watts surge.

CAUTION!

Do not tamper with engine governed speed.

The TITAN INDUSTRIAL GENERATOR supplies cor-
rect rated frequency and voltage when running at the
proper governed speed. Incorrect frequency and/or volt-
age could damage connected electrical devices.

It is required by The National Electrical Code to have
the frame and all external conductive parts of the gen-
erator connected to an earth ground. Proper grounding
also satisfies most local electrical codes.

Connect a No. 12 AWG standard copper wire to the
Grounding Lug Block (See Figure 1). The grounding
lug can be found on the control panel. Connect the other
end of the wire to an earth driven copper or brass ground-
ing rod (electrode).

CAUTION!

Do not connect ground to a preexisting

ground rod, water pipe, or building frame.

Consult with a licensed electrician in your area because
local codes vary. Properly grounding the generator helps
prevent electrical shock if a ground fault condition exists
in the generator or in connected electrical devices. This
will also help to dissipate static electricity resulting from
ungrounded devices.

GROUNDING THE GENERATOR

Figure #1 - Grounding Lug Block

Summary of Contents for TG 9000ES

Page 1: ...strength generating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used WARNING Do Not O...

Page 2: ...TION THE TITAN INDUSTRIAL INC MODEL TG 9000ES is a gas engine driven revolving field alternating current AC generator designed to supply electrical power for com patible electrical tools motors applia...

Page 3: ...ise dam aged electrical cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive...

Page 4: ...or WARNING DO NOT start or stop generator with electri cal devices plugged in Allow the generator engine to run at a No Load condition for several minutes to stabilize inter nal engine temperature bef...

Page 5: ...vel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset the...

Page 6: ...Control Panel Remote Ignition must be in the run position to operate Turn ignition off to avoid battery drian when not in use...

Page 7: ...10 32oz...

Page 8: ...12 Storage...

Page 9: ...0 Device Running Watts Device Running Impact Wrench 500 Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 BTU 400...

Page 10: ...10...

Page 11: ...nual Start 11hp Titan Gasoline Engine Steel Sleeve Cylinder 5 Gallon Fuel Tank Approx Run Time 10hrs 50 Load TITAN INDUSTRIAL P O Box 791 Travelers Rest S C 29690 800 845 4141 www titanindustrial net...

Page 12: ...Box 791 Travelers Rest SC 29690 Phone 864 834 7212 Fax 864 834 5127 Service Replacement Parts 800 845 4141 www titanindustrial net MODEL 9000ES Industrial Generator MODEL TG 9000ES Industrial Generat...

Reviews: