OPERATION OF THE GENERATOR

1. Check oil and Gas for proper levels
2. Turn fuel valve to the ON postiton
3. Turn stop switch to the On position
4. Pull choke lever to the ON position
5. Grip recoil starter and pull briskly
6. Once started return choke lever to the OFF
positon.
7. Let engine settle before hooking up any
electrical appliances.

Connecting electrical loads

Let engine stabilize and warm up for at least 3
minutes.
Make sure devices to be connected are in good
working order and in the “OFF” position before
connecting to the generator.
Make sure to plug in desired devices into the cor-
rect receptacle.
DO NOT connect 240 Volt loads to the 120 Volt
duplex receptacles.
DO NOT connect 3 phase loads to the genera-
tor.
DO NOT connect 50 Hz loads to the generator.
This is a 60Hz system.
DO NOT overload the generator. Add up the rated
Watts of all loads to be connected. This total
should not exceed the total watts of the genera-
tor.

Stopping the engine

Turn off all electrical devices connected to the
generator.

WARNING:
DO NOT start or stop generator with electri-
cal devices plugged in.

Allow the generator engine to run at a ‘No Load’
condition for several minutes to stabilize inter-
nal engine temperature before stopping

Turn the On\Off Switch on the Control Panel to
the “off” position.

Turn Fuel Valve to the “Off” position

Generator maintenance

(see maintenance table for list below).

Keep the generator clean and dry. Use a damp
cloth to clean exterior surfaces. Remove caked
on dirt with a soft brush.

Never spray with water. Water can contaminate
the engine fuel system and cause serious prob-
lems in the generator.

Damage may occur if engine or carburetor clean-
ing products are used.

Starting the engine

4

Check/Refill Fuel

X

Drain fuel from tank

X

Check/Refill Oil

X

Check for oil leakage

X

Check battery fluid

X

Change oil

* X

Clean/Replace oil filter

N\A

Replace air filter

X*

Clean/Replace fuel filter

X

Maintenance Guide

DAILY EVERY MONTH/ 30 HRS EVERY 3 MONTHS/ 100 HRS EVERY 6 MONTHS/ 500 HRS

*First oil change should be after the first (5) hours of use.After initial break-in period change oil every (30) hours.

Use SAE 30 oil.

X*Air filter may need to be replaced frequently, due to adverse conditions. Check filter frequently.

Summary of Contents for TG 9000ES

Page 1: ...strength generating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used WARNING Do Not O...

Page 2: ...TION THE TITAN INDUSTRIAL INC MODEL TG 9000ES is a gas engine driven revolving field alternating current AC generator designed to supply electrical power for com patible electrical tools motors applia...

Page 3: ...ise dam aged electrical cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive...

Page 4: ...or WARNING DO NOT start or stop generator with electri cal devices plugged in Allow the generator engine to run at a No Load condition for several minutes to stabilize inter nal engine temperature bef...

Page 5: ...vel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset the...

Page 6: ...Control Panel Remote Ignition must be in the run position to operate Turn ignition off to avoid battery drian when not in use...

Page 7: ...10 32oz...

Page 8: ...12 Storage...

Page 9: ...0 Device Running Watts Device Running Impact Wrench 500 Jet Pump 800 Lawn Mower 1200 Light Bulb 100 Microwave Oven 700 Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 BTU 400...

Page 10: ...10...

Page 11: ...nual Start 11hp Titan Gasoline Engine Steel Sleeve Cylinder 5 Gallon Fuel Tank Approx Run Time 10hrs 50 Load TITAN INDUSTRIAL P O Box 791 Travelers Rest S C 29690 800 845 4141 www titanindustrial net...

Page 12: ...Box 791 Travelers Rest SC 29690 Phone 864 834 7212 Fax 864 834 5127 Service Replacement Parts 800 845 4141 www titanindustrial net MODEL 9000ES Industrial Generator MODEL TG 9000ES Industrial Generat...

Reviews: