11. Troubleshooting
Fault
Cause
Remedy
The tool is blocking during the
operation, or the welding
process, due to this fact it isn’t
possible to extract the tool from
the strap.
The sealing mechanic is
blocking.
Remove and reinsert the Li-Ion
battery straight. The blockade
should be dissolved because the
control system moves the sealing
mechanism in basic position.
Should the fault not have been
remedied, contact TITAN service
dept.
Li-Ion battery plugged into tool,
but the tool doesn’t work.
Li-Ion battery defective or
insufficiently charged.
Check charge of Li-Ion battery and
recharge or, if required, replace it.
Contacts of Li-Ion battery or the
tool polluted or defective.
Visual inspection of the contacts;
clean and straighten them, if
required.
Loose cable connections.
Check the cable connections and fix
them if required.
Progressive abatement of Li-Ion
battery duty cycles.
Li-Ion battery defective or
insufficiently charged.
Check charge of Li-Ion battery and
recharge or, if required, replace it.
Then use the charged Li-Ion battery
again and check (count) if there is
an improved cycle time.
Life of Li-Ion battery moves
towards its end, internal cells
are defective or exhausted.
Use new Li-Ion battery.
Charger does not start charging
and/or flashes red.
Contacts of Li-Ion battery or the
tool, polluted or defective.
Visual inspection of the contacts;
clean and straighten them, if
required.
Mains plug of the charger
isn’t in
the socket, or charger is
defective.
Check if the mains plug is in the
socket, and put the socket in if
required. Check charger for
function.
Li-Ion battery is defective.
Do not use the Li-Po storage battery
any further and replace it with a new
Li-Po storage battery.
Work parameters like tensioning
force and welding time cannot
be entered and/or do not remain
saved.
Circuit board
(120)
or circuit
board control
(117)
is defective.
Contact TITAN
– Service.
Pressing the push-button 2
doesn’t start the welding
operation.
Push-button 2
(109)
, welding
motor
(503)
and/or circuit board
(120)
defective, or loose cable
connection.
Visual check for loosen cable
connection, re-establish the cable
connection if required. Contact
TITAN-Service.
H TA750 EU 46/17