22
© Titan Enterprises Ltd
PulsiteLink_Instruction_Manual_0722
12.54
No Power
Analog
Current
output (4mA-20mA)
Wiring disconnected
No external power to meter
Analog
Voltage
3.22
OK
Analog
Voltage
output (0V-5V/10V)
3.22
No Power
Analog
Voltage
output (0V-5V/10V)
No external power to meter
5 LED Indicators
The Pulsite Link has two LED indicators.
Left Hand Side
Right Hand side
GREEN
Power >6VDC
GREEN
flashing
Pulse Output (only)
YELLOW/GREEN
Power <6VDC
Analog output: VDC
or Not Selected
BLUE
flashing
Analog output (only)
RED
4-20mA
Output
selected but not
connected
TURQUOISE
flashing
Pulse and Analog
out
BLUE
Communication/
settings sent