The chart below shows the various display messages for the operating functions. During
operation only one message will be shown for each parameter.
Parameter
Value
Condition Description
Additional Comments
Flow
12.54
Rate of Flow
Raw Flow Reading (without
viewing filter)
Input (Hz)
647.97
Input Frequency
Frequency measure from
connected flowmeter
NPN Output
Off
High
Not Used
NOTE: Will Read +VDC if pull
up connected
237
No Power
237
Active
Output
Pulse
Frequency (Hz)
Off
High
Output Alarm State
No Alarm
+VDC
On
Low
Output Alarm State
Alarm Triggered
0VDC
On
Low
Output Alarm State
Invert Selected
No Alarm
0VDC
Off
High
Output Alarm State
Invert Selected
Alarm Triggered
+VDC
PNP Output
Off
Low
Not Used
NOTE: Will Read +VDC if pull
up connected
237
No Power
Output
Pulse
Frequency (Hz)
No +VDC. The PNP will not
work on USB power alone
237
Active
Output
Pulse
Frequency (Hz)
Off
Low
Output Alarm State
No Alarm
0VDC
On
High
Output Alarm State
Alarm Triggered
+VDC
On
High
Output Alarm State
Invert Selected
No Alarm
0V
Off
Low
Output Alarm State
Invert Selected
Alarm Triggered
0VDC
Analog
Current
12.54
OK
Analog
Current
output (4mA-20mA)