The  chart  below  shows  the  various  display  messages  for  the  operating  functions.  During 
operation only one message will be shown for each parameter. 

Parameter 

Value 

Condition  Description 

  Additional Comments 

Flow 

12.54 

 

Rate of Flow 

 

Raw  Flow  Reading  (without 
viewing filter) 

Input (Hz) 

647.97 

 

Input Frequency 

 

Frequency  measure  from 
connected flowmeter 

NPN Output 

Off  

High  

Not Used 

 

NOTE: Will Read +VDC if pull 
up connected 

 

237 

No Power   

 

 

 

237 

Active 

Output 

Pulse 

Frequency (Hz) 

 

 

 

Off 

High 

Output Alarm State 

 

No Alarm 
+VDC 

 

On 

Low 

Output Alarm State 

 

Alarm Triggered 
0VDC  

 

On 

Low 

Output Alarm State 

 

Invert Selected 
No Alarm 
0VDC 

 

Off 

High 

Output Alarm State 

 

Invert Selected 
Alarm Triggered 
+VDC 

PNP Output 

Off  

Low  

Not Used 

 

NOTE: Will Read +VDC if pull 
up connected 

 

237 

No Power 

Output 

Pulse 

Frequency (Hz) 

 

No  +VDC.  The  PNP  will  not 
work on USB power alone 

 

237 

Active 

Output 

Pulse 

Frequency (Hz) 

 

 

 

Off 

Low 

Output Alarm State 

 

No Alarm 
0VDC 

 

On 

High 

Output Alarm State 

 

Alarm Triggered 
+VDC  
 

 

On 

High 

Output Alarm State 

 

Invert Selected 
No Alarm 
0V 

 

Off 

Low 

Output Alarm State 

 

Invert Selected 
Alarm Triggered 
0VDC 

Analog 
Current 

12.54 

OK 

Analog 

Current 

output (4mA-20mA) 

 

 

Summary of Contents for Pulsite Link

Page 1: ...Titan Enterprises Ltd www flowmeters co uk PulsiteLink_Instruction_Manual_0722...

Page 2: ...o NPN and PNP The Pulsite Link pulse convertor can also provide o Flow alarm switches via NPN and PNP output terminals Disclaimer This information has been reviewed and believed to be correct at the t...

Page 3: ...l Failure to follow these guidelines may result in damage to the equipment or personal injury Manufacture Information The Pulsite Link pulse convertor is designed and manufactured by Titan Enterprises...

Page 4: ...uch as o NPN o PNP o Reed Switch The Pulsite Link pulse convertor will provide linearized outputs of o 4 20mA active o 0 5V o 0 10V The Pulsite Link pulse convertor can also provide o Flow alarm switc...

Page 5: ...5 Titan Enterprises Ltd www flowmeters co uk PulsiteLink_Instruction_Manual_0722...

Page 6: ...h max 400Hz VDC Supply to meter Flowmeter 5V Out 0VDC Supply to Flowmeter Flowmeter 0V Pulse from flowmeter Flowmeter Sensor Supply 5Vdc 50mA max room temperature 25mA at high temperature Pull up down...

Page 7: ...7 Titan Enterprises Ltd www flowmeters co uk PulsiteLink_Instruction_Manual_0722 3 1 1 Wiring Diagrams...

Page 8: ...8 Titan Enterprises Ltd www flowmeters co uk PulsiteLink_Instruction_Manual_0722...

Page 9: ...9 Titan Enterprises Ltd www flowmeters co uk PulsiteLink_Instruction_Manual_0722 NOTE Best practice is to place Pull up down Resistor near target device...

Page 10: ...ng Software screen NOTE When correctly connected the bars will rotate in the bottom left had corner and you should see All Controls enabled On connecting Pulsite Link the Software will normally automa...

Page 11: ...you wish to connect By opening another copy of the Titan Interface Software you can connect and modify multiple meters from the same computer The panel below shows the main menu function icons of the...

Page 12: ...shown in the software they can be retrieved from the nonvolatile memory of the flow meter by pressing the looking glass icon 4 1 3 Test Outputs This tab enables the user to manually set outputs on the...

Page 13: ...eter to present the flow and outputs Flow Details Shows the user real time data from the meter including flow and outputs Multiple Window Display To aid set up whilst operating the meter it is possibl...

Page 14: ...eter is fundamentally a volumetric device but a density figure can be entered here if one of the mass units is selected Caution must be used however as there is no temperature density correction Cut O...

Page 15: ...lue will give a recommended lowest flow for the input calibration k factor and the chosen Analog Response Time Setting the cut off value below the recommended level means when the flow is between the...

Page 16: ...opposite at zero Volt 4 3 3 2 NPN Output PNP Output If Output is selected in Pin assignments the output options are Pulse Single or Dual flow alarm 4 3 3 2 1 Pulse Enter the number of pulses per unit...

Page 17: ...n can be adjusted with the Invert check box Hysteresis This is used to prevent fluttering of the alarm signal when flow is around the threshold level The value is set around the Threshold value For ex...

Page 18: ...ggered The remaining settings in the input box are the same as for Single Flow alarms The alarm will automatically activate and reset in proportion to the user set Hysteresis of the Threshold levels T...

Page 19: ...Powered VDC and ON Unpowered 0VDC Using the PNP OFF Unpowered 0VDC and ON Powered VDC 4 3 3 4 Analog Outputs NOTE FOR FULL ANALOG OUTPUT FUNCTION EXTERNAL POWER OF 15VDC IS REQUIRED Analog Output the...

Page 20: ...is operating e g relay status and frequency output if these options are selected Parameters Flow This is the instantaneous flow rate and is updated approximately every 100 milliseconds Input The measu...

Page 21: ...wer 237 Active Output Pulse Frequency Hz Off High Output Alarm State No Alarm VDC On Low Output Alarm State Alarm Triggered 0VDC On Low Output Alarm State Invert Selected No Alarm 0VDC Off High Output...

Page 22: ...10V 3 22 No Power Analog Voltage output 0V 5V 10V No external power to meter 5 LED Indicators The Pulsite Link has two LED indicators Left Hand Side Right Hand side GREEN Power 6VDC GREEN flashing Pu...

Page 23: ...Time User Configurable 100ms 1s or 10s Option in software Accuracy 4 20mA output 0 012 linearity 0 15 maximum total output error 16 Bit resolution and monotonicity 0 10 Volt output 0 1 linearity 0 5...

Page 24: ...he diagrams in the manual No Pulse Output on wire or showing on Titan Interface Software Incorrect settings Check Settings installation No analog output Incorrect Configuration Check that the correct...

Page 25: ...Connection Return to Titan Enterprises for repair Titan Interface Software is not showing all Tabs User Settings Flow Details Advanced Datalogging Software is placing the tab window outside the monit...

Reviews: