22
© Titan Tool Inc. All rights reserved.
Fluid Section Assembly
1
2
30
4
3
5
7
6
8
11
12
14
15
16
17
18
19
20
21
22
23
13
10
9
24
25
26
27
29
28
42
43
31
32
33
34
35
36
38
37
39
40
41
Install upper packing
with raised lip and
o-ring facing down.
O-Ring
Raised Lip
NOTE: When using “HOT” solvents, replace
Viton o-ring (item 36) with optional
PTFE
o-ring
(P/N 700-897). Install with o-ring tool (P/N 700-890).
Install lower packing with
the side that has the o-ring
closest to the top of the
packing facing up.
Closer
Top
NOTE: When repacking the fluid section, make
sure the raised lip on the bottom of the
lower packing is fully outside the packing
around the piston rod after insertion of
the piston rod.