Cleanup
Special cleanup instructions for use with flammable solvents:
• Always flush spray gun preferably outside and at least one
hose length from spray pump.
• If collecting flushed solvents in a one gallon metal
container, place it into an empty five gallon container, then
flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
The pump, hose, and gun should be cleaned thoroughly
after daily use. Failure to do so permits material to cake,
seriously affecting the performance of the unit.
Always spray at minimum pressure with the gun nozzle tip
removed when using mineral spirits or any other solvent
to clean the pump, hose, or gun. Static electricity buildup
may result in a fire or explosion in the presence of
flammable vapors.
Flushing the Unit
Flush the unit with the solvent appropriate to the material
being used after daily use (use solvents at room temperature).
The unit should then be flushed again with mineral spirits.
For long term storage, flush the unit with an appropriate oil
before storing.
1. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
2. Remove the gun tip and soak in a container filled with a
solution appropriate to the type of material being sprayed.
3. Check to be sure the pressure control knob is turned fully
counterclockwise to its lowest setting.
4. Prepare a container of solvent appropriate to the type of
material being sprayed.
5. Move the engine ON/OFF switch to the ON position and
start the engine.
6. Move the pump ON/OFF switch to the ON position.
7. Slowly turn the pressure control knob clockwise to increase
the pressure until fluid starts to come out of the return hose.
8. Tilt the siphon tube above the material container and allow
the unit to pump itself dry through the return hose.
9. Remove the material container and replace it with the
container of appropriate solvent.
10. Allow the appropriate solvent to circulate through the unit
for 2–3 minutes.
11. Turn the pressure control knob fully counterclockwise to
its lowest setting.
12. Turn the PRIME/SPRAY valve up to its SPRAY position.
13. Turn the pressure control knob clockwise to increase
pressure.
14. Hold the gun against the side of a metal container and
trigger the gun into the container until solvent comes out
and the pump, hose, and gun are clean.
15. Turn the pressure control knob fully counterclockwise to
its lowest setting.
16. Turn the PRIME/SPRAY valve to PRIME. Remove the
siphon tube from the solvent container.
17. Turn the pressure control knob clockwise to increase
pressure and allow the unit to pump itself dry through the
return tube.
18. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
19. Store in a clean, dry area.
WARNING
CAUTION
WARNING
Maintenance
Before proceeding, follow the “Pressure Relief Procedure”
in the Operation section of this manual. Additionally,
follow all other warnings to reduce the risk of an injection
injury, injury from moving parts or electric shock. Always
unplug the sprayer before servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips Screwdriver
3/8" Hex Wrench
Needle Nose Pliers
5/16" Hex Wrench
Adjustable Wrench
1/4" Hex Wrench
Rubber Mallet
3/16" Hex Wrench
Flat-blade Screwdriver
5/32” Hex Wrench
1/2" Open End Wrench
1. Before repairing any part of the sprayer, read the
instructions carefully, including all warnings.
2. When disconnecting wires, use needle nose pliers to
separate mating connectors.
Never pull on a wire to disconnect it. Pulling on a wire
could loosen the connector from the wire.
3. Test your repair before regular operation of the sprayer to
be sure that the problem is corrected. If the sprayer does
not operate properly, review the repair procedure to
determine if everything was done correctly. Refer to the
Troubleshooting Charts to help identify other possible
problems.
4. Make certain that the service area is well ventilated in
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
5. If you have any further questions concerning your TITAN
Airless Sprayer, call TITAN:
Customer Service (U.S.) .......................
1-800-526-5362
Fax ................................................
1-800-528-4826
Customer Service (Canada) ..................
1-800-565-8665
Fax ................................................
1-905-856-8496
Customer Service (International)...........
1-201-405-7520
Fax ................................................
1-201-405-7449
CAUTION
NOTE: Refer to the Parts Lists and Service
Instructions section of this manual for detailed
service instructions.
WARNING
© Titan Tool Inc. All rights reserved.
7