background image

3

SAFETY

Do not remove jammed logs 

with your hands.

Caution! Thrown objects.

Before  starting  any  repair 

maintenance  or  cleaning, 

always disconnect the power.

A v o i d   i n j u r y   f r o m   t h e  

movement 

of 

the 

splitting  blade.

Keep bystanders away from 

the working area.

Do  not  split  wood  when  

transporting your machine.

Do  not  split  wood  when 
your machine is leaning.

Safety Warnings & Instructions

UNDERSTAND YOUR LOG SPLITTER

INSPECT YOUR LOG SPLITTER

DRESS PROPERLY

PROTECT YOUR EYES AND FACE

EXTENSION CORDS

DRUGS, ALCOHOL AND MEDICATION 

AVOID DANGEROUS CONDITIONS

Read  and  understand  the  owner's 

manual  and  labels  affixed  to  the  log 

splitter.  Learn  its  application  and 

limitations  and  take  note  of 

the  potential  hazards  caused  by 

misuse.  Familiarise  yourself  with 

the  machine controls  and their proper 

operation.

Do not operate the log splitter while 
under the influence of drugs, alcohol, 
or any medication that could affect 
your ability to use it properly.

Always  operate  your  log  splitter  on  dry, 

solid,  level  ground.  Never  operate  your 

log splitter on slippery, wet, muddy, or icy 

surfaces. The location you choose should 

be free from any tall grass, brush, or other 

interferences. There should be plenty of 

room

 

for

 

operation.

 

Keep

 y

our

 w

ork 

area

 

tidy

 

and

 

well

 

lit.

 

Cluttered areas

 

can cause 

injuries.

 

To

 

avoid

 

tripping,

 

do

 

not  leave  tools,  logs,

 

or other 

components laying around the work 

area. 

Check your log splitter before turning 
i t   o n .   K e e p   g u a r d s   i n   p l a c e   a n d 
in working order. Form a habit of 
checking to see that keys and adjusting 
wrenches are removed from tool area 
before turning it on. Replace damaged, 
missing or failed parts before using 
it. Make sure all nuts, bolts, screws, 
hydraulic fittings, hose clamps, etc. are 
securely tightened. Always check the 
oil level in the hydraulic oil tank. Never 
operate your log splitter when it is in 
need of repair or is in poor mechanical 
condition. Before starting work, test 
the stopping devices to keep them in 
safe working condition.

Do not wear loose clothing, gloves, 
neckties or jewelry (rings, wrist watches). 
They can be caught in moving parts. 
Protective electrically non-conductive 
gloves, non-skid footwear and hearing 
protection are recommended when 
working. Wear protective hair covering 
to contain long hair, preventing it from 
get caught in machinery.

Any log splitter may throw foreign 
objects into the eyes. This can cause 
permanent eye damage. Always wear 
safety goggles. Everyday eyeglasses 
have only impact resistant lenses. They 
are not safety glasses. 

Improper use of extension cords may 
cause inefficient operation of the log 
splitter which can result in overheating. Be 
sure the extension cord is no longer than 
10m and its section is no less than 2.5mm

2

 

to allow sufficient current flow to the 
motor. Avoid use of free and inadequately 
insulated connections. Connections must 
be made with protected material suitable 
for outdoor use. 

Do  not  use  the  log  splitter  in  wet  or 
damp areas

,

 or expose it to rain. Do not

use  it  in  areas  where  fumes  from  paint, 
solvents  or  flammable  liquids  pose  a 
potential hazard.

Summary of Contents for TPLS11TV

Page 1: ...TY READ AND UNDERSTAND THE ENTIRE MANUAL BEFORE OPERATING MACHINE Both model number and serial number may be found on the main label You should record both of them in a safe place for future use Hydra...

Page 2: ...ou many years of dependable service Carefully read through this entire operator s manual before using your new log splitter Take special care to heed the cautions and warnings Always recycle your unwa...

Page 3: ...it on Keep guards in place and in working order Form a habit of checking to see that keys and adjusting wrenches are removed from tool area before turning it on Replace damaged missing or failed parts...

Page 4: ...ties and capacities Never try to split logs larger than those indicated in the specifications table Unplug when not in use before making adjustments changing parts cleaning or working on the log split...

Page 5: ...ssure 25 2 Mpa Hydraulic Oil Capacity 7 0 L Ram Travel 85 cm Speed Forward 13 9 cm s 2 9 cm s Retract 3 7 cm s Noise Pressure Level LpA 80 db A Vibration 2 5 m s Overall Sizes Length 144 cm Width 133...

Page 6: ...e stored or transported und er ambient temperatures between 25 C and 55 C ELECTRICAL REQUIREMENTS With a 230 Volt 50Hz motor the log splitter should be connected to standard 230V 10 50Hz 1 Electrical...

Page 7: ...ve the R Pin and bolt to release cylinder Lower both control handles to raise the wedge ram to the top Insert the bolt and R Pin to secure the cylinder 2 3 4 1 2x20 2 A 3 Release both control handles...

Page 8: ...n with clip for easier delivery Remove the clip and pin lower the handle in the direction of the arrow as shown and secure it by fixing the pin with clip to the outer hole Pull the spring pin and slid...

Page 9: ...achine with the crane SPLITTER OPERATION a Bleed the air out of the hydraulic system before starting the log splitter The cover of the hydraulic oil tank should be loosened by some rotations until air...

Page 10: ...slowly then press it to the end until the log is completely split 3 Return the splitter wedge to the starting position Operate the spring loaded retract control lever to lift the wedge above the heig...

Page 11: ...hands Never use another people to help you with freeing jammed log Break log in the direction of its growing grain Do not place log across the log splitter for splitting It may be dangerous and may s...

Page 12: ...or flat spots on the edge Read dipstick to determine the maximum and minimum oil level Low oil can damage the oil pump Overfilling can result in excessive temperature in the hydraulic transmission sy...

Page 13: ...the connecting parts being loose Check and tighten the parts Control levers or connection parts bent Repair the bent parts Low hydraulic oil level Check and refill hydraulic oil Log splitter works wit...

Page 14: ...14 PARTS SCHEMATIC...

Page 15: ...Shaft 1 31 Extended Log Fixing Claw 1 32 Nut M8 3 33 Log Fixing Claw 1 No Description Q ty 34 Locknut M8 4 35 Large Washer 8 6 36 Wing Bolt M8x25 1 37 Bolt M8x20 3 38 Lower Hose 1 39 Combined Washer...

Page 16: ...er Pin 2x20 2 88 Wheel Axle 1 89 Locknut M16 2 90 Bolt 8 8 M16x90 2 No Description Q ty 91 Screw Plug 1 92 Combined Washer 22 1 93 Main Frame 1 94 Bolt 8 8 M6x12 4 95 Flat Washer 6 4 96 Buffer Spring...

Page 17: ...magnetic Compatibility Directive 2005 88 EC Noise Emission in the Environment by equipment for use outdoors Directive Standards and technical specifications referred to EN 609 1 2017 EN 55014 1 2017 E...

Reviews: