background image

2

INTRODUCTION

ENVIRONMENTAL

SYMBOLS

TABLE OF CONTENTS

Introduction 

Symbols

Safety

Contents Supplied

Assembly

Deliverying Log Splitter To Work Site

Splitter Operation 

Transport

Free a Jammed Log

Replacing Oil

Sharpening Wedge

Wiring Diagram

Parts Schematic

Trouble Shooting

Hydraulic System Diagram

Spe

cificat

ions

Sa

f

ety Warnings 

&

 In

s

tr

uc

t

ions

2

2

3

3

5

6

7

9

9

8

11

11

12

13

14

13

13

Your new Titan Pro 11 ton log 

splitter has been designed to more 

than satisfy your expectations, 

following in our long line of quality 

garden machinery products. It has 

been manufactured under 
stringent 

quality standards  i n  

o r d e r   t o   o f f e r   a higher level of 

performance. You will find your new 

unit easy and safe to operate, and with 

proper care, it will give you many years 

of dependable service.

Carefully  read  through  this 
entire  operator's  manual 
before  using  your  new  log 
splitter.  Take  special  care 
to  heed  the  cautions  and 
warnings.

Always 

recycle 

your 

unwanted  materials  instead  of 

disposing  of  them  as  waste. 

All  tools,  hoses and  packaging 

should  be  taken to  your  local 

recycling 

center 

and 

disposed 

of 

in 

an 

environmentally safe way. 

The  rating  plate  on  your 

machine shows  a  number  of 

symbols.  These represent important 

information  about the product, or 

instructions on its use.

Read  these 

instructions in full 

before  using  the 

machine.

Wear appropriate footwear!

Wear protective gloves!

Wear eye protection!

Wear hearing protection!

Keep your work space 

tidy! Untidiness  may 

result  in accidents.

Do  not  remove  or  tamper 

with any protection or 

safety devices.

Dispose of the used oil in 

an environmentally-friendly 

way.

Do not use in the rain.

Danger! Keep clear of 

moving parts!

Certificate of Conformity

1

7

Summary of Contents for TPLS11TV

Page 1: ...TY READ AND UNDERSTAND THE ENTIRE MANUAL BEFORE OPERATING MACHINE Both model number and serial number may be found on the main label You should record both of them in a safe place for future use Hydra...

Page 2: ...ou many years of dependable service Carefully read through this entire operator s manual before using your new log splitter Take special care to heed the cautions and warnings Always recycle your unwa...

Page 3: ...it on Keep guards in place and in working order Form a habit of checking to see that keys and adjusting wrenches are removed from tool area before turning it on Replace damaged missing or failed parts...

Page 4: ...ties and capacities Never try to split logs larger than those indicated in the specifications table Unplug when not in use before making adjustments changing parts cleaning or working on the log split...

Page 5: ...ssure 25 2 Mpa Hydraulic Oil Capacity 7 0 L Ram Travel 85 cm Speed Forward 13 9 cm s 2 9 cm s Retract 3 7 cm s Noise Pressure Level LpA 80 db A Vibration 2 5 m s Overall Sizes Length 144 cm Width 133...

Page 6: ...e stored or transported und er ambient temperatures between 25 C and 55 C ELECTRICAL REQUIREMENTS With a 230 Volt 50Hz motor the log splitter should be connected to standard 230V 10 50Hz 1 Electrical...

Page 7: ...ve the R Pin and bolt to release cylinder Lower both control handles to raise the wedge ram to the top Insert the bolt and R Pin to secure the cylinder 2 3 4 1 2x20 2 A 3 Release both control handles...

Page 8: ...n with clip for easier delivery Remove the clip and pin lower the handle in the direction of the arrow as shown and secure it by fixing the pin with clip to the outer hole Pull the spring pin and slid...

Page 9: ...achine with the crane SPLITTER OPERATION a Bleed the air out of the hydraulic system before starting the log splitter The cover of the hydraulic oil tank should be loosened by some rotations until air...

Page 10: ...slowly then press it to the end until the log is completely split 3 Return the splitter wedge to the starting position Operate the spring loaded retract control lever to lift the wedge above the heig...

Page 11: ...hands Never use another people to help you with freeing jammed log Break log in the direction of its growing grain Do not place log across the log splitter for splitting It may be dangerous and may s...

Page 12: ...or flat spots on the edge Read dipstick to determine the maximum and minimum oil level Low oil can damage the oil pump Overfilling can result in excessive temperature in the hydraulic transmission sy...

Page 13: ...the connecting parts being loose Check and tighten the parts Control levers or connection parts bent Repair the bent parts Low hydraulic oil level Check and refill hydraulic oil Log splitter works wit...

Page 14: ...14 PARTS SCHEMATIC...

Page 15: ...Shaft 1 31 Extended Log Fixing Claw 1 32 Nut M8 3 33 Log Fixing Claw 1 No Description Q ty 34 Locknut M8 4 35 Large Washer 8 6 36 Wing Bolt M8x25 1 37 Bolt M8x20 3 38 Lower Hose 1 39 Combined Washer...

Page 16: ...er Pin 2x20 2 88 Wheel Axle 1 89 Locknut M16 2 90 Bolt 8 8 M16x90 2 No Description Q ty 91 Screw Plug 1 92 Combined Washer 22 1 93 Main Frame 1 94 Bolt 8 8 M6x12 4 95 Flat Washer 6 4 96 Buffer Spring...

Page 17: ...magnetic Compatibility Directive 2005 88 EC Noise Emission in the Environment by equipment for use outdoors Directive Standards and technical specifications referred to EN 609 1 2017 EN 55014 1 2017 E...