Table 7
Parameter description
Parameter value
1.
6
.2.1
The controller is assembled on
board
(104х68) and designed for installation inside the
turnstile body or power supply box. The controller appearance is shown in
Figure 6
. 19 LEDs are
installed on the controller board. Their purpose is as follows:
•
LED “POWER” initiates availability of power supply voltage 5V;
•
LED “OPERATE” initiates operability of microprocessor;
•
7 LEDs initiate state of outputs for peripheral connections “OUT1» ÷ «OUT7”;
•
3 LEDs “SENSOR” initiate state of rotor position sensor;
•
LEDs «RX» and «TX» initiate respectively reception and transmittance in serial port.
40 terminals are installed on the board: 14 of them are designed for external connections, the rest
are designed for connection to the turnstile units or are standby.
1.6.2.2 Technical features
The controller technical features are shown in
Table 7
.
Number of inputs for acquisition of control commands
5
Number of signal outputs
7
Type of inputs
logical
Type of outputs
open collector
Logical «1» voltage
(3
5)
V
Logical «0» voltage
(0
2,2)
V
Maximum peak voltage applied to inputs «IN1»÷« IN8»
15
V
Peak voltage switched by signal output transistors
50
V
Peak current switched via signal outputs
0,1 А
Controller supply voltage
(9
15)
V
Maximum consumption current
0,15 А
Number of serial ports of signal reception and transmission
(RS-485)
1
Climatic modification and location category according to GOST
15150-69
MC
4
1.
6
.2.3
Description of operation
The controller operates according to the program entered into microprocessor memory. The
turnstile mechanism and LED displays are controlled according to control commands and status
of rotor position sensors based on the logic downloaded into program. Control commands can be
transmitted via RS485 (from control panel) or logical inputs (by closing and opening of inputs
“INP1” ÷ “INP5” on “GND”).
The controller (along with the turnstile) can be in the INITIAL STATE (closed for access) or in
the following access modes: