| tisira
Figure 19.4
Sealing control;
Open the isolation valve or natural gas valve and apply soap water with ample
foam to the connection point to controls to check for gastightness.
Never test with a naked flame.
Final control
1.
Plug the power cable into the socket and activate fuse of the equipment.
2.
Control the functions.
Placement
Place your product after you control the required power and gas connection.
When placing, make sure that the gas hose and power cable is not near the hot
surface of the product.
When placing, make sure that the gas hose and power cable have not been
damaged.
Set your product to the kitchen counter as a minimum according to the
dimensions shown in the Figure 8.
Figure 8
Remove the burner cover and burner as shown in the Figure 19.
Remove the injector by help of 7’s socket screw driver as shown in
the Figure 19.1.
Fix the injector (D) you want to convert as shown in the Figure 19.2
(see Table 1).
Put the burner in place again as shown in the Figure 19.3.
Upon completion of the conversion, then burn the burners in order
and remove the switch on the control panel and adjust the low flame
length by tightening or untightening the screw on the gas valve (19.4
cock) or inside the valve shaft.