www.tisira.com
| tisira
GAS CONNECTION
The gas connection is male 1/2” BSP and is
situated 55mm from the right and 560mm
from the floor.
Loosen the tie-in down and connect one
terminal of the pipe with the gas elbow between
1-1.2m long.
The hose should not be subjected to abrasion,
kinking or permanent deformation and should
be able to be inspected along its entire length
after installation.
Unions compatible with the hose fittings must
be used and connections tested for gas leaks.
The flexible tube shall be fitted in such a way
that it cannot come into contact with a moveable
part of the housing unit (e.g. a drawer)and does
not pass through any space susceptible of
becoming congested.
The fixed consumer piping outlet should be at
approximately the same height as the cooker
connection point, pointing downwards and
approximately 150mm to the side of the cooker.
The hose should be clear of the floor when the
cooker is in the installed position.
Once the appliance has been installed, make
sure that the gas pipe is neither squashed or
damaged by moving parts.
Before switching the appliance on, check
that it is correctly regulated for the type of
gas available.
ADJUSTMENT TO DIFFERENT
GAS TYPES
To perform the adjustments to different types
of gas, the qualified installer shall follow the
instructions given on this section.
Make sure that the gas supply pressure
respects the values presented in the table
“Burner and nozzle specifications” on page 18.
NATURAL GAS
This appliance leaves the factory set to operate
using Natural Gas.
Make sure that the Natural Gas regulator
supplied with the appliance is installed and,
with the triple ring burner operating at its
maximum, adjust the test point pressure to
1.0kPa.
UNIVERSAL LPG
To convert from Natural Gas to Universal
LPG, ensure that the Natural Gas regulator is
replaced by the Test Point Assembly supplied
with the appliance. Adjust the test point
pressure to 2.75kPa.
To adapt the appliance to a gas different from
that for which it was set up (see gas type
label inside the warming compartment door)
proceed as follows:
1. Remove the trivets
2. Remove the burners caps and diffusers
3. With a 7 mm socket spanner unscrew and
remove the injectors.
4. Replace the injectors with those supplied
corresponding to the gas available (see
burner and injector characteristics table)
5. Replace the various parts proceeding in
reverse.