86 of 90
11 Gas supply
Caution
Risk of explosion
•
Modifications to build-in units, the gas system or the electrical
system may only be performed by authorized specialist personnel.
A separate compartment is provided in the kitchen block on the right side in order to store two gas
cylinders of 5 kg each. The gas cylinder compartment can only be accessed from the outside via a
lockable door.
In the cabin a gas system according to regulations is installed, with pressure regulator and safety
valve, cylinder racks and shut-off valves for individual consumers.
Using the SecuMotion pressure regulator (30 mb), one gas cylinder each can be connected for the
operation of the following appliances:
•
Cooker
•
Heater (standard equipment)
•
Heater / hot water (L equipment)
•
Refrigerator.
SecuMotion pressure regulator
1
Quick-action stop valve
2