Set up menu commands: 

LIST OF COMMANDS 

 

 

 

Press  the  OK  button  on  the  home  screen  of  respective  mode  to  enter  in  the  setup 
mode.  

M1 Steps/ Rev: 

Motor 1 steps/ Revolution. 

The number of steps that motor 1 moves in one revolution. The range is 0001 to 9999.

 

M2 Steps/ mm: 

Motor 2 steps/mm.  

The number of steps that motor 2 moves in one mm. The range is 0001 to 9999.

 

M1 Speed: 

Motor 1 speed decides the maximum speed with which the motor 1 moves. Its range 
can be 0001 to 9999 RPM. However, the value for maximum speed depends on motor 
1 steps/revolution value. 

M2 Speed: 

Motor  2  speed  parameter  decides  the  maximum  speed  with  which  the  Y-axis  motor 
moves. Its speed range can be 0001 to 9999 RPM. However, the value for maximum 
speed depends on motor 1 steps/revolution value. 

M1Accel (value) range is 01 to 20 

This command is used to set acceleration for motor 1.  

 

 

M2Accel (value) range is 01 to 20 

This command is used to set acceleration for motor 2.  

 

 

M1 Dir:  

This  parameter  decides  the  direction  of  motor  1,  whether  to  move  clockwise  or 
counterclockwise when the start button is pressed. Motor1 jogs too in direction as set 
here. 

M2 Dir:  

This  parameter  decides  the  direction  of  motor  2,  whether  to  move  clockwise  or 
counterclockwise when the start button is pressed. Motor2 jogs too in the direction as 

Summary of Contents for TNC-G10

Page 1: ...ING THE FOLLOWING PRODUCT TNC G10 SURFACE GRINDER CONTROLLER TINY CONTROLS AND THE TINY CONTROLS COMPANY S LOGO ARE COPYRIGHTS OF TINY CONTROLS PVT LTD OTHER TRADEMARKS TRADE NAMES AND SERVICE MARKS O...

Page 2: ...RMINALS 5 OPRATING THE SURFACE GRINDER CONTROLLER 1 HOME SCREEN 2 JOGGING 3 SETUP SCREEN 6 7 7 MODES 1 SENSORS ENABLED MODE 1 MODE 2 MODE 3 2 SENSORS DISABLED MODE 1 MODE 2 MODE 3 8 8 8 9 10 11 11 12...

Page 3: ...W CW M2Dir CCW CW M1Accel M2 Accel M1HSpeed M2HSpeed Motion commands M1Steps Rev M2 Steps mm SPECIFICATION FEATURES Supply Voltage 90V to 250V AC 50Hz 60Hz Max Pulse Rate 40 KHz Overall Size 165mm x 1...

Page 4: ...navigate the cursor However in the home screen these keys are used to alter the speed and feed value These keys are used to jog the motor1 and motor2 in jog menu 3 OK Esc OK Press OK to enter in Setup...

Page 5: ...13 X STP STEP PULSE OUTPUT for motor 1 i e motor for X axis Connect to STEPPER DRIVER eq TSTEP 484 14 X DIR DIRECTION output for motor 1 i e motor for X axis Connect to STEPPER DRIVER eq TSTEP 484 15...

Page 6: ...tive home position and searches for home sensor input The home speed can be adjusted in Set up screen for respective mode NOTE If Emergency input is received anytime the motion is halted and current o...

Page 7: ...ress Ok button to enter in the set up screen of the respective mode selected Jogging Jogging can be done by pressing left and right navigation keys for motor1 motor X and by pressing up and down navig...

Page 8: ...nsors mounted Press Ok in Home screen and enter in Setup menu Enable the M_SENSOR for automatic motion after being sensors sensed Here are discussed functioning of all the modes when the sensors are e...

Page 9: ...homing of motor2 takes place When motor2 reaches at its home position if mode 1S was set in home screen both the motors stop at home position and direction of motor1 is saved Press start stop key to c...

Page 10: ...n is commenced again after reaching the motor2 at its home position and whole process repeats as illustrated above Press start stop key to pause the motion in between the process MODE 3 Press key3 to...

Page 11: ...R sets motor2 to move left or right when being operated Press Esc key in Home screen to enter in Jog menu Press Key 0 to set the coordinates for motor1 and motor2 as zero coordinates Screen shot when...

Page 12: ...distance in left and the process continues This process continues until Motor2 reaches its limit position Y 10 as the limit for motor2 is set in jogging screen for manual setting of limits When motor...

Page 13: ...reaches to Y limit controller waits for the motor1 to reach the limit position and after it motor2 moves to its home position If mode 2S was set in home screen motion for both the motor stops when mo...

Page 14: ...s Operation when sensors are enabled Modes Modes Patterns Operations Mode1 Feed at both sides 1 Motor1 moves CCW 2 Motor2 moves CCW 3 Motor1 moves CW 4 Same as step 1 Mode 2 Feed at one end only 1 Mot...

Page 15: ...one end only 1 Motor1 moves CCW 2 Motor1 moves CW 3 Motor2 moves CCW 4 Same as step 1 Mode 3 No feed 1 Motor1 moves CCW 2 Motor1 moves CW 3 Same as step 1 Homing Homing feature is available on key 8 I...

Page 16: ...n value M2 Speed Motor 2 speed parameter decides the maximum speed with which the Y axis motor moves Its speed range can be 0001 to 9999 RPM However the value for maximum speed depends on motor 1 step...

Page 17: ...Speed This parameter decides maximum home speed in RPM It is the maximum speed of motor 2 that it achieves for home Its range is 1 to 9999 RPM however its value depends on motor 2 steps mm value M_SEN...

Page 18: ...18 CONNECTION DIAGRAM...

Reviews: