16
Set up menu commands:
LIST OF COMMANDS
Press the OK button on the home screen of respective mode to enter in the setup
mode.
M1 Steps/ Rev:
Motor 1 steps/ Revolution.
The number of steps that motor 1 moves in one revolution. The range is 0001 to 9999.
M2 Steps/ mm:
Motor 2 steps/mm.
The number of steps that motor 2 moves in one mm. The range is 0001 to 9999.
M1 Speed:
Motor 1 speed decides the maximum speed with which the motor 1 moves. Its range
can be 0001 to 9999 RPM. However, the value for maximum speed depends on motor
1 steps/revolution value.
M2 Speed:
Motor 2 speed parameter decides the maximum speed with which the Y-axis motor
moves. Its speed range can be 0001 to 9999 RPM. However, the value for maximum
speed depends on motor 1 steps/revolution value.
M1Accel (value) range is 01 to 20
This command is used to set acceleration for motor 1.
M2Accel (value) range is 01 to 20
This command is used to set acceleration for motor 2.
M1 Dir:
This parameter decides the direction of motor 1, whether to move clockwise or
counterclockwise when the start button is pressed. Motor1 jogs too in direction as set
here.
M2 Dir:
This parameter decides the direction of motor 2, whether to move clockwise or
counterclockwise when the start button is pressed. Motor2 jogs too in the direction as
Summary of Contents for TNC-G10