 Operation when sensors are disabled: 

Press  Ok  in  Home  screen  and  enter  in  Setup  menu.  Disable  M_SENSOR  in  Setup 

mode. This operation is chosen if  limits are to be  set by user manually. Follow these 

steps to set the manual limits: 

 Press Ok in the Home screen and enter in Setup menu. 

 Disable the M_SENSOR in Setup menu and press Ok to save it.  

 Set  the  Y-FEED  DIR  as  left/  right  as  per  requirement.  Y-FEED  DIR  sets  motor2  to 

move left or right when being operated. 

 Press Esc key in Home screen to enter in Jog menu.  

 Press Key 0 to set the coordinates for motor1 and motor2 as zero coordinates. 

 

 

 

 

Screen shot when the Zero Coordinates are made 

 Press Ok key to edit and set the desired limits using numeric keys. Press Ok key to 

save these values and Esc key to discard the value. 

Here are discussed all the modes in manual limit settings operation: 

MODE  1: 

Press  key  1  to  select  the  mode1  and  key  4  to  set  stop  or  continuous  in 

Home screen. The pattern for Mode 1 is shown below.  

 

 

 

 

Screen shot when the Mode 1 is selected 

Summary of Contents for TNC-G10

Page 1: ...ING THE FOLLOWING PRODUCT TNC G10 SURFACE GRINDER CONTROLLER TINY CONTROLS AND THE TINY CONTROLS COMPANY S LOGO ARE COPYRIGHTS OF TINY CONTROLS PVT LTD OTHER TRADEMARKS TRADE NAMES AND SERVICE MARKS O...

Page 2: ...RMINALS 5 OPRATING THE SURFACE GRINDER CONTROLLER 1 HOME SCREEN 2 JOGGING 3 SETUP SCREEN 6 7 7 MODES 1 SENSORS ENABLED MODE 1 MODE 2 MODE 3 2 SENSORS DISABLED MODE 1 MODE 2 MODE 3 8 8 8 9 10 11 11 12...

Page 3: ...W CW M2Dir CCW CW M1Accel M2 Accel M1HSpeed M2HSpeed Motion commands M1Steps Rev M2 Steps mm SPECIFICATION FEATURES Supply Voltage 90V to 250V AC 50Hz 60Hz Max Pulse Rate 40 KHz Overall Size 165mm x 1...

Page 4: ...navigate the cursor However in the home screen these keys are used to alter the speed and feed value These keys are used to jog the motor1 and motor2 in jog menu 3 OK Esc OK Press OK to enter in Setup...

Page 5: ...13 X STP STEP PULSE OUTPUT for motor 1 i e motor for X axis Connect to STEPPER DRIVER eq TSTEP 484 14 X DIR DIRECTION output for motor 1 i e motor for X axis Connect to STEPPER DRIVER eq TSTEP 484 15...

Page 6: ...tive home position and searches for home sensor input The home speed can be adjusted in Set up screen for respective mode NOTE If Emergency input is received anytime the motion is halted and current o...

Page 7: ...ress Ok button to enter in the set up screen of the respective mode selected Jogging Jogging can be done by pressing left and right navigation keys for motor1 motor X and by pressing up and down navig...

Page 8: ...nsors mounted Press Ok in Home screen and enter in Setup menu Enable the M_SENSOR for automatic motion after being sensors sensed Here are discussed functioning of all the modes when the sensors are e...

Page 9: ...homing of motor2 takes place When motor2 reaches at its home position if mode 1S was set in home screen both the motors stop at home position and direction of motor1 is saved Press start stop key to c...

Page 10: ...n is commenced again after reaching the motor2 at its home position and whole process repeats as illustrated above Press start stop key to pause the motion in between the process MODE 3 Press key3 to...

Page 11: ...R sets motor2 to move left or right when being operated Press Esc key in Home screen to enter in Jog menu Press Key 0 to set the coordinates for motor1 and motor2 as zero coordinates Screen shot when...

Page 12: ...distance in left and the process continues This process continues until Motor2 reaches its limit position Y 10 as the limit for motor2 is set in jogging screen for manual setting of limits When motor...

Page 13: ...reaches to Y limit controller waits for the motor1 to reach the limit position and after it motor2 moves to its home position If mode 2S was set in home screen motion for both the motor stops when mo...

Page 14: ...s Operation when sensors are enabled Modes Modes Patterns Operations Mode1 Feed at both sides 1 Motor1 moves CCW 2 Motor2 moves CCW 3 Motor1 moves CW 4 Same as step 1 Mode 2 Feed at one end only 1 Mot...

Page 15: ...one end only 1 Motor1 moves CCW 2 Motor1 moves CW 3 Motor2 moves CCW 4 Same as step 1 Mode 3 No feed 1 Motor1 moves CCW 2 Motor1 moves CW 3 Same as step 1 Homing Homing feature is available on key 8 I...

Page 16: ...n value M2 Speed Motor 2 speed parameter decides the maximum speed with which the Y axis motor moves Its speed range can be 0001 to 9999 RPM However the value for maximum speed depends on motor 1 step...

Page 17: ...Speed This parameter decides maximum home speed in RPM It is the maximum speed of motor 2 that it achieves for home Its range is 1 to 9999 RPM however its value depends on motor 2 steps mm value M_SEN...

Page 18: ...18 CONNECTION DIAGRAM...

Reviews: