5.1.3 Error codes DPC18
5.1.4 DPC18 error messages
You may see an error message in the display if something goes wrong in the electronic system. The
error messages have the following codes:
Contact a technician to correct the error message. The display will not return to normal until the
problem is resolved. The drive will not be functional until then.
Error code
Definition
Solution
“07”
High voltage protection
Check the battery voltage
“08”
Error with engine hall sensor inside
Have your dealer check the engine stator
“10”
Engine temperature has reached the
maximum protection value
Stop riding and wait until the LED stops blinking
“12”
Error with power sensor in controller
Have your dealer check the sensor
“13”
Error with temperature sensor in battery
Check the battery
“21”
Error with speed detection sensor
Check the engine stator
“22”
BMS Communication error
Replace the battery
“30”
Communication error
1. Check the connectors between the EB-BUS and
the controller
2. Replace the controller
Number
Definition
Solution
0
Normal
Normal situation; no action required
1
Short circuit in the system / incorrect voltage Contact a technician
2
Error in pedal sensor
Contact a technician
3
Problem with power supply to the engine
Contact a technician
4
Defect in engine housing
Contact a technician
5
Brake problem
Contact a technician
6
Low voltage -> battery is empty
Charge the battery
7
Engine trouble (stalls)
Contact a technician
8
Communication error controller
Contact a technician
9
Communication error display
Contact a technician