20
7.2
How to Replace the C-Power LV-Unit
a) Turn the protection cover on the drive unit counterclockwise and remove it.
b) Remove the empty C-Power LV-unit. The display will indicate “LC” and the red LED will be blinking.
c) Remove the used battery set from the drive unit. The display indicates “LO.”
d) Insert the new battery set into the drive unit, following the directions of the arrows. The display will
again indicate “LC.”
e) Remove the plug of the C-Power LV-unit.
f) Push the C-Power LV-unit into the protection cover until lubricant comes out of the opening.
(Refer to figure 6, chapter 4).
g) Place the new C-Power LV-unit on the drive unit. Turn it until the catch locks in place and the teeth
of the C-Power LV-unit and the drive unit interlock. The control system will automatically recognize
the new C-Power LV-unit. The display will indicate “– –“ if the Timken C-Power was switched off prior
to the replacement of the C-Power LV-unit. It will indicate “99% Vol.“ if the Timken C-Power was
switched on before the replacement. Use only completely full Timken C-Power LV-units, to help
guarantee trouble-free operation.
h) The lubrication system will resume operating with the previous setting of the discharge period.
i) If necessary, the discharge period of the lubricator can be changed (refer to chapter 6.8).
If the lubricator was switched on prior to the replacement of the C-Power LV-unit, the discharging
process will automatically begin using the previous settings of the discharge period. If the lubricator
was switched off, the discharging process must be started by pushing the ON/OFF/SELECT button.
(Refer to figure 13, chapter 6.5)