CONNECTOR INSTALLATION
Carefully inspect the completed wiring before connecting the TIMEMASTER.
WIRE
COLOR
PIN# USED FOR
purple
1
24 volt pulse to mechanical coin counter
orange/black 2
coin pulse from coin acceptor
green/black
3
last minute horn (24 volts DC ground)
red/black
4
last minute horn (24 volts DC hot)
light green
5
safety ground
blue/black
6
timed output
yellow
7
jumpered (DO NOT USE)
yellow
8
jumpered(DO NOT USE)
green
9
TIMEMASTER power (24 volts AC
neutral)
orange
10
TIMEMASTER power (24 volts AC hot)
Pin #1
COIN COUNTER PULSE (output) See Figure 3.
A 24 volt AC pulse is output on pin 1 in response to an input from pin 2 each time a coin is deposited. Normally, this pin is connected to one terminal of a mechanical coin
counter in the equipment room for accounting purposes.
Pin #2
COINT ACCEPTOR PULSE (input) See Figure 3.