![TimeIPS IPS300T Installation Manual Download Page 7](http://html1.mh-extra.com/html/timeips/ips300t/ips300t_installation-manual_1117389007.webp)
Mounting the TimeIPS Server
The TimeIPS IPS300T/IPS320T/IPS400T server is designed to be operated on a
shelf, on a table, on the floor, or mounted in a standard 19" rack.
For rack mounting, secure the server with 4 rack screws (not provided). If desired,
a rail kit, part number CASE-RAIL, is available for purchase from TimeIPS.
TimeIPS servers must have reasonable clearance and air circulation to prevent
overheating.
Power Backup (UPS)
As with any server, a steady supply of clean power is essential for TimeIPS.
•
Losing power while the server is operating may cause data loss or
corruption.
•
Brown-outs or flickering power can cause damage to the power supply
and/or system components.
To prevent damage and/or data loss related to power problems, we recommend
plugging the TimeIPS server into a UPS (Uninterruptible Power Supply).
TimeIPS servers are relatively low-power devices. A UPS with a minimum rating
of 1000VA is recommended for maximum power stability and moderate run-time.
TimeIPS servers have support for communicating with most APC brand Smart-UPS
units with USB data cables. The signals from these UPS units allow TimeIPS to log
and report power outages and perform a clean automated shutdown in the event of
an extended outage. This will protect your data and is highly recommended.
TimeIPS
http://support.timeips.com 316.264.1600
Page 7