background image

Repeat this process to set additional network parameters, such as your Subnet Mask,
Gateway, Primary DNS server and Secondary DNS server.  You may also specify 
your NTP server if you know its IP address.  If you know your NTP server by its 
name (such as ntp.yourcompany.com) you will need to use a USB keyboard or enter
this information through the web interface.  Be sure to select “Apply Settings” to 
save your changes.

If you have set your clock to a static IP address you can easily change it back to 
DHCP.  You will need to be an administrative user.  Access the menu and navigate 
to “Configure Network.” Scroll down to “Revert to DHCP” and press Enter.

You will need to select “Apply Settings.”  In some cases, you may need to perform a
full restart or power cycle for the change to take effect.

IPS125T-B Biometrics Mounting

The IPS125T-B unit should be mounted at approximately eye-level for employees to
use the biometric option most successfully.

The IPS125T-B must be mounted so that fingers can be placed flat against the 
sensor as shown on the left.  The biometric sensor WILL NOT WORK with the tip 
of the finger on the sensor as shown on the right.

Note:  Keep the fingerprint sensor clean with a soft, dry cloth. Do NOT use cleaning
products on the unit as they will damage the sensor.

Page 12

http://support.timeips.com  316.264.1600

TimeIPS

 Reverting to DHCP

  Show Network Info
  Set Master IP
­>Revert to DHCP
  Set IP Address

Be sure to select Apply Settings to 
save your changes.

X

CORRECT

INCORRECT

Summary of Contents for IPS125T

Page 1: ...IPS125T TimeIPS Network Clock and Keypad Installation Guide including instructions for IPS125T B Touch and IPS125T O Optical Biometric Fingerprint Reader Options...

Page 2: ...cations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be dete...

Page 3: ...ast 13 Train Employees and Keypad Commands 14 IPS125T B O Biometrics Training 15 Technical Support 16 System Specifications 16 IPS125T Series Overview The TimeIPS IPS125T is a Network Time Clock that...

Page 4: ...Ethernet module The optional PoE module allows a PoE network switch or PoE injector to provide power to the network clock over the network cable In the case of a power outage you may want to keep the...

Page 5: ...ation that would expose the unit to direct sunlight Prolonged exposure to sunlight may cause overheating and or other damage The unit will become warm during normal use This does NOT indicate malfunct...

Page 6: ...5VDC Positive Center power adapter or optional TimeIPS PoE Power Over Ethernet adapter Connecting any other adapter or power supply may damage the IPS125T and will void the warranty Connect employee...

Page 7: ...n be used The cable routing on the back of the keypad allows the keypad to be mounted above below or to either side of your TimeIPS IPS125T Network Clock Connect the USB cable to a free USB port on th...

Page 8: ...oll down to Set Master IP and press Enter You should see a screen similar to this Page 8 http support timeips com 316 264 1600 TimeIPS After the employee identification device s and network cable are...

Page 9: ...2 If no network connection was detected you should see the following screen If you see this screen check the network cable on the back of the TimeIPS unit Unplug and reconnect the network cable at bot...

Page 10: ...ions per clock via the Clock Configuration page These settings are independent of any employee badge or PIN numbers Pressing the BS key at any time will take you up one level in the menu system Page 1...

Page 11: ...Apply Changes to store your settings B To set a static IP address through the clock menu you must be an administrative user Access the menu and navigate to the Full System Menu Scroll down to Configu...

Page 12: ...You will need to select Apply Settings In some cases you may need to perform a full restart or power cycle for the change to take effect IPS125T B Biometrics Mounting The IPS125T B unit should be moun...

Page 13: ...stem will give to each new employee 2 Assign a unique number in the ID Badge Number field as needed If you want each employee to have their own custom number such as their driver s license number or S...

Page 14: ...mple 111222333 enter Hours remaining only show for hourly employees If Your System Includes Job Tracking A successful clock in out will generate an in or out message and the LCD display will indicate...

Page 15: ...enrollments per employee If employees have trouble matching fingerprints try 10 enrollments on 2 fingers 5 times per finger in different positions Employee Training Read the biometrics section of the...

Page 16: ...port website http support timeips com Support e mail support timeips com Support phone number 316 264 1600 This manual is copyright 2004 2015 TimeIPS Inc TimeIPS and the TimeIPS logos are registered t...

Reviews: