PIR coverage is 
poor/sporadic.

Unit may be poorly located. See previous section – 

‘Selecting The Location’ and re-locate the unit.

Detection range 
varies from day 
to day.

PIR sensors are influences by climatic conditions. 
The colder the ambient temperature, the more effective 
the sensor will be.

The floodlight 
will only activate 
for a maximum 
of 15 seconds 
when in normal 
operating mode.

The floodlight could be affected by its own light output. 
Tilt the PIR sensor further downwards and away from 
the floodlight. Once the floodlight has settled into the 
new time settings, re-angle the PIR sensor back to your 
desired position.

Unit activates during 
the daytime.

The level of ambient light in the area may be too dark 
for the current DUSK setting. During daylight, adjust the 
DUSK control slightly anti-clockwise. When the lamp 
turns off, enter the detection area. If the PIR still activates, 
the setting is still too high. Repeat the above procedure 
until the PIR does not activate when you enter the 
detection area. Refer to the previous section for 
more details.

Summary of Contents for Sure time STFL10PIRB

Page 1: ...LED PIR Floodlight Models STFL10PIRB STFL20PIRB STFL30PIRB STFL50PIRB...

Page 2: ...ed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications Energy Usage 10kWh 1000h 230VAC 50Hz These luminaires are of class I construction and must be earthed ColourTemper...

Page 3: ...painted walls Mounting the detector near heat sources such as heating vents air conditioning units lights etc Pointing the detector towards objects that may move in the wind such as curtains tall plan...

Page 4: ...ll using the U bracket supplied as a template 5 2 Drill the holes for the wall plugs ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface 5 3 Fix...

Page 5: ...n to the isolating switch and test for correct operation Connectthe3coremainssupplycable fromtheunitasfollows LIVE Brown or Red L NEUTRAL Blue or Black N EARTH Green Yellow E connect to main power bro...

Page 6: ...he floodlight under auto mode Test Procedure Adjust the Time knob to fully anti clockwise and Lux knob is set to the Sun setting Switch the power On Walk across the detection area once to detector is...

Page 7: ...6 The detector head can be turned 90 left or right by hand and can be tilted 70 downward Tilt upward 70 Tilt downward 70 Tilt upward 40 Tilt downward 70 Pan right 90 Pan left 90...

Page 8: ...Adjust the knob as desired LUX knob setting When setting the Lux knob at MOON the floodlight will only operate in the dark When setting the Lux knob at SUN the floodlight will operate in any light le...

Page 9: ...unit will now illuminate continuously for 6 hours then switched back into Auto Mode Switch the internal wall switch circuit breaker once OFF ON within 2 seconds To switch the unit back into Auto Mode...

Page 10: ...y activate the sensor Sometimes passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to allow detection of cars people using public thoroughfares adjac...

Page 11: ...wn light output Tilt the PIR sensor further downwards and away from the floodlight Once the floodlight has settled into the new time settings re angle the PIR sensor back to your desired position Unit...

Page 12: ...ith proof of purchase and it will be replaced free of charge For year 2 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases Fo...

Page 13: ...TG IQ V1...

Reviews: