1

1. General Information

These instructions should be read carefully and retained for further reference 
and maintenance.

2. Safety

  Before installation or maintenance, ensure the mains supply to the luminaire 

is switched off and the circuit supply fuses are removed or the circuit breaker 
turned off.

  It is recommended that a qualified electrician is consulted or used for 

the installation of this luminaire and install in accordance with the 
current IEE wiring and Building Regulations.

  Check that the total load on the circuit including when this luminaire is fitted 

does not exceed the rating of the circuit cable, fuse or circuit breaker.

3. Technical Specifications

  Energy Usage: 

 

10kWh/1000h

  230V AC, 50Hz

  These luminaires are of class I construction and must be earthed 

  Colour Temperature: 

4000K

  IP65 Rated suitable for restricted external applications

  Detection Angle: 

110°

  Detection Range: 

Up to  10 metres

  Time On Adjustment: 

3 seconds to 18 minutes

  Dusk Level Adjustment: 

Day and Night or Night only operation

  CE Approved 

STFL10PIRB

  10W LED Non replaceable lamp

STFL30PIRB

• 

30W

 LED Non replaceable

 

lamp

  Energy Usage: 

 

30kWh/1000h

  Lumen Output: 2700lm 

STFL50PIRB

• 

50W LED Non replaceable lamp

• 

 

Energy Usage: 50kWh/1000h

  Lumen Output: 4500lm

  

  Lumen Output: 900lm 

STFL20PIRB

  20W LED Non replaceable lamp

  Energy Usage: 20kWh/1000h

  Lumen Output: 1800lm

•  Energy Efficiency:                    Class A+

Summary of Contents for Sure time STFL10PIRB

Page 1: ...LED PIR Floodlight Models STFL10PIRB STFL20PIRB STFL30PIRB STFL50PIRB...

Page 2: ...ed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications Energy Usage 10kWh 1000h 230VAC 50Hz These luminaires are of class I construction and must be earthed ColourTemper...

Page 3: ...painted walls Mounting the detector near heat sources such as heating vents air conditioning units lights etc Pointing the detector towards objects that may move in the wind such as curtains tall plan...

Page 4: ...ll using the U bracket supplied as a template 5 2 Drill the holes for the wall plugs ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface 5 3 Fix...

Page 5: ...n to the isolating switch and test for correct operation Connectthe3coremainssupplycable fromtheunitasfollows LIVE Brown or Red L NEUTRAL Blue or Black N EARTH Green Yellow E connect to main power bro...

Page 6: ...he floodlight under auto mode Test Procedure Adjust the Time knob to fully anti clockwise and Lux knob is set to the Sun setting Switch the power On Walk across the detection area once to detector is...

Page 7: ...6 The detector head can be turned 90 left or right by hand and can be tilted 70 downward Tilt upward 70 Tilt downward 70 Tilt upward 40 Tilt downward 70 Pan right 90 Pan left 90...

Page 8: ...Adjust the knob as desired LUX knob setting When setting the Lux knob at MOON the floodlight will only operate in the dark When setting the Lux knob at SUN the floodlight will operate in any light le...

Page 9: ...unit will now illuminate continuously for 6 hours then switched back into Auto Mode Switch the internal wall switch circuit breaker once OFF ON within 2 seconds To switch the unit back into Auto Mode...

Page 10: ...y activate the sensor Sometimes passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to allow detection of cars people using public thoroughfares adjac...

Page 11: ...wn light output Tilt the PIR sensor further downwards and away from the floodlight Once the floodlight has settled into the new time settings re angle the PIR sensor back to your desired position Unit...

Page 12: ...ith proof of purchase and it will be replaced free of charge For year 2 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases Fo...

Page 13: ...TG IQ V1...

Reviews: