8
9. Manual Override Mode
The light can be switched on for longer time periods by use of the
Manual Override Mode. This can be activated at night by using
the internal wall switch or circuit breaker.
•
The unit will now illuminate continuously for 6 hours, then switched
back into Auto Mode.
•
Switch the internal wall switch/circuit breaker once (OFF/ON)
within
2
seconds.
•
To switch the unit back into Auto Mode, switch the internal wall switch/circuit
breaker once (OFF/ON) within
2
seconds. The unit will operate as set up after
the walk test procedure.
Activation
within 2s
Automode
Deactivation
6hr
or
within 2s