background image

Remove the cover from the terminal block. Diagram D. 
PIeRCe & PASS THe CABLe THROUGH THe GROMMeT BeFORe PROCeeDInG. 
It is recommended that the grommet is pierced with a screwdriver to ensure a better seal.  
Allow approximately 50mm of cable to pass through the grommet.
Fit the grommet into its location, ensuring a good seal.
Fix the mounting plate to the wall. Take care not to overtighten the screws to prevent damage 
to the mounting plate. If using a power screwdriver, use the lowest torque setting.

CONNECTION

Connect the cable to the terminal block on the unit as follows (see connection diagram):
neUTRAL (Blue)  

n

eARTH (Green/Yellow)
LIVe (Brown)  

L

ensure that the connections are secure.
Install the lamp.
ensure no wires are trapped.
Refit the terminal block cover and front cover (reversal of removal) ensuring all clips are firmly 
located.

Isolation 
Switch