background image

11

5. Commissioning

Switch on the mains supply to the Control Unit and check the 
left hand ‘Supply On’ indicator (green) is illuminated. The ‘Fault’ 
(yellow) and ‘Alarm’ (blue) indicators should be off.

If the Fault indicator is illuminated this almost certainly 
indicates that there is an open or short circuit in the extra low 
voltage wiring. Assuming the Fault indicator is off pull the pull 
cord and the system should behave as described in the second 
paragraph of section 2.

Having observed this to be the case press the Reset button on 
the Control Unit to end the alarm. Pull the pull cord again and 
verify each unit is performing correctly then press the Reset 
button on the Reset Unit to end the alarm.

6. Diagnostics

Warning : Switch off mains supply before removing 
the front cover or dismantling the control unit. 
Remove all power source including battery when 
wiring any part of the system.

The following possible faults and solutions are for guidelines 
only. If in doubt contact the Timeguard Helpline on 

020 8450 0515

Summary of Contents for EACP1

Page 1: ...Unit Single Zone Stainless Steel Control Unit Plastic Reset Unit Stainless Steel Reset Unit Plastic Over Door Unit Stainless Steel Over Door Unit Pull Cord Unit Four Zone Plastic Control Unit Four Zo...

Page 2: ...Plastic Over Door Unit EADF1 Stainless Steel Over Door Unit EASSDF1 Pull Cord Unit EAPC1 Four Zone Plastic Control Unit EACP4 with battery back up EACP4PR Four Zone Stainless Steel Control Unit EASSCP...

Page 3: ...2 Typical Single Zone System Available as EASZK Pull Cord Unit Over Door Unit Reset Unit Single Zone Control Unit 2 wire 2 wire 2 wire Fused Spur not supplied...

Page 4: ...of the four zone Control Units in combination with the appropriate number of Reset Units Over Door Units and Pull Cord Units There are no adverse effects if any of the four zone control units input c...

Page 5: ...ted intermittently and will both be further reassuring the person in distress At the Control Unit the alarm light and the sounder are activated continuously Either the Over Door Unit or the Control Un...

Page 6: ...ot connect to mains supply Wiring and Fixing Holes Final page gives expanded view of this diagram MUST be switched off at all times while installation is in progress The installation shall be carried...

Page 7: ...ional wiring rules Bring the mains supply cable 1mm2 TFE into the box and connect the Live and Neutral wires to the terminals on the Control Unit marked L and N respectively see diagram Ensure the len...

Page 8: ...to the wall box using the screws provided Insert battery into battery holder Connections are as above diagram for a single zone system The four zone system is similar except that the four zone Contro...

Page 9: ...oor knot the cord at required height Hold the unit backplate in position on the ceiling and mark through the xing holes on the unit backplate and drill and plug if necessary holes suitable for four No...

Page 10: ...input see diagram Fix the Reset Unit to the wall box using the screws provided 3 3 Over Door Unit This should be sited to attract appropriate personnel to the area where assistance is required An exa...

Page 11: ...voltage applied to the L and N terminals An illustration of full reserve capability is as follows Single zone system Typically 4 days on standby with 2 hours continuous alarm Four zone system 1 day on...

Page 12: ...ld behave as described in the second paragraph of section 2 Having observed this to be the case press the Reset button on the Control Unit to end the alarm Pull the pull cord again and verify each uni...

Page 13: ...running on backup battery check that the battery is fully charged Blue LED on Control Unit is continuously ON and cannot be reset 2 wire link is shorting Battery is too low Check there is no short ci...

Page 14: ...ve battery Metal Hydride rechargeable PP3 9Volt Alarm Output DC voltage through 470 ohm resistor Do not connect to mains voltage source Maximum pull force on pull cord 200N Reset button marking Visual...

Page 15: ...Unit Rear Reset Selection Connector for incoming mains supply Transformer Battery Holder Back up PR versions only Fixing Holes Fixing Holes Cover Fixing Holes Pull Cord Hole Fixing Holes Fixing Holes...

Page 16: ...For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND 020 8452 1112 or email csc timeguard com HELPLINE 020 8450 0515 67 058 192 Iss 1...

Reviews: