W415-0865 / 04.07.10
9
2.4.3 EPA COMPLIANCE
2.4.2 SAFETY FEATURES
This appliance is EPA exempt from Phase II
prerequisites, but complies with Oregon /
Washington emissions requirements.
We suggest that our pellet hearth
products be installed and serviced by
professionals who are certified in the U.S.
by the National Fireplace Institute
®
(NFI)
as NFI Pellet Specialists or who are
certified in Canada by
Wood Energy Technical
Training (WETT).
www.nficertified.org
66.1A
HIGH LIMIT SWITCH:
Your appliance is equipped with a high limit switch. In the event that the temperature of
the appliance approaches an unsafe operating temperature, this switch will shut down the pellet feed, which
will eventually shut down the unit. If this happens, it is important to
fi
nd out why the unit overheated. Contact
your local dealer.
LOW LIMIT SWITCH:
This switch will automatically shut down the appliance if the
fi
re goes out or fails to light
within 15 minutes.
HOPPER DOOR INTERLOCK:
Your appliance is equipped with a micro switch in the hopper assembly that
shuts-off the auger when the hopper door is opened. Closing the door switches the auger back on, allowing
pellets to feed again.
VACUUM SWITCH:
This switch will sense lack of air
fl
ow through the appliance and shut down the pellet feed.
This lack of
fl
ow could be caused by a blocked vent.
POWER FAILURE:
In the event of a power failure, the appliance will shut down. Once power is restored, the
appliance will re-start, unless the convection air temperature has gone above the high limit switch setting. If
this happens, contact your local dealer.
2.5 RATING PLATE INFORMATION
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP
CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.
U.S. ENVIROMENTAL PROTECTION AGENCY Certified to comply with July 1992 Particulate Emission Standards
MODEL TPS35 LISTED PELLET FUEL BURNING ROOM HEATER TESTED TO:
ASTM E 1509, ULC/ORD C1482-M90, ULC S627
TPSI35
Straight Installation
Corner Installation
MINIMUM CLEARANCES TO COMBUSTIBLE
SIDE
6”
REAR
3”
CORNER
2”
CEILING
48”
INPUT RATING
MIN
1.5
LB/HR
MAX
4.5
LB/HR
ELECTRICAL RATING
120V 3.6A 60HZ
Floor
Protection
Through
Wall
Installation
3”
6”
- INSTALL AND USE ONLY IN ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS AND LOCAL
BUILDING CODES.
- MINIMUM CEILING HEIGHT: 7FT (2.13M) HEARTH
EXTENSION / COMBUSTIBLE FLOOR PROTECTION: IF
INSTALLED ON A COMBUSTIBLE FLOOR, UNIT MUST BE
PLACED ON A NON-COMBUSTIBLE FLOOR PROTECTOR
EXTENDING 6” IN FRONT.
- DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
- REPLACE GLASS WITH ONLY CERAMIC GLASS.
DANGER:
RISK OF ELECTRICAL SHOCK. DISCONNECT
POWER BEFORE SERVICING UNIT.
- KEEP VIEWING AND ASH REMOVAL DOORS TIGHTLY CLOSED DURING OPERATION.
- CONTACT LOCAL BUILDING AND FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR LOCAL AREA.
- SUITABLE FOR USE IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLA-
TION KIT.
- REFER TO INSTALLATION INSTRUCTIONS OR LOCAL BUILDING CODES WHEN
PASSING EXHAUST SYSTEM THROUGH COMBUSTIBLE WALL OR CEILING.
-
FUEL:
FOR USE WITH PELLET FUEL ONLY.
Floor Protection
6”
Through
Wall Vents
45°
2”
2”
45°
Elbow
Floor Protection
6”
Interior
Vertical
Vent
2”
2”
Tee
MADE IN / FABRIQUÉ AU:
WOLF STEEL LTD. BARRIE, ONTARIO CANADA
24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y8 CANADA
NAC GUANGZHOU P.R.C.
NO.69 HEFENG ROAD, GUANGZHOU,CHINA
REFERENCE # W/N
16544
ATTENTION :
L'APPAREIL EST CHAUD LORSQU’IL FONCTIONNE. NE PAS
TOUCHER. TENIR LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES À
L’ÉCART. LE CONTACT PEUT CAUSER DES BRÛLURES DE PEAU.
Certifié conforme à la norme d'émanation de particules de juillet 1992 du U.S. ENVIROMENTAL PROTECTION AGENCY
W385-0498
- INSTALLER ET UTILISER CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET
AUX CODES DU BÂTIMENT LOCAUX.
- HAUTEUR DE PLAFOND MINIMALE 7 PI. (2,13 m)
BASE DE PROTECTION/PROTECTION DE PLANCHER COMBUSTIBLE : SI INSTALLÉ
SUR UN PLANCHER COMBUSTIBLE, L’APPAREIL DOIT ÊTRE PLACÉ SUR UNE
PLAQUE PROTECTRICE INCOMBUSTIBLE S’ÉTENDANT SUR 6” À L’AVANT.
- NE PAS RACCORDER CET APPAREIL À LA CHEMINÉE D’UN AUTRE APPAREIL.
- REMPLACER LA VITRE PAR UNE VITRE EN CÉRAMIQUE SEULEMENT.
DANGER :
RISQUE DE SECOUSSE ÉLECTRIQUE. DÉBRANCHER L’ALIMENTATION
ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN.
- GARDER LA PORTE VITRÉE ET LA PORTE DU TIROIR À CENDRES BIEN FERMÉES
DURANT LE FONCTIONNEMENT.
- CONTACTER LES AUTORITÉS LOCALES DU BÂTIMENT ET DU SERVICE DES
INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS D’INSTALLATION
DANS VOTRE RÉGION.
- PEUT ÊTRE INSTALLÉ DANS UNE MAISON MOBILE SI INSTALLÉ CONJOINTEMENT
AVEC UNE PRISE D’AIR EXTÉRIEUR.
- SE RÉFÉRER AUX INSTRUCTIONS D’INSTALLATION OU AUX CODES DU BÂTIMENT
LOCAUX LORSQUE LE SYSTÈME D’ÉVACUATION TRAVERSE UN MUR OU UN
PLAFOND COMBUSTIBLES.
-
COMBUSTIBLE :
POUR USAGE AVEC DES GRANULES SEULEMENT.
Installation droite
Installation de coin
MODÈLE TPS35 APPAREIL DE CHAUFFAGE AUX GRANULES HOMOLOGUÉ
T
ESTÉ SELON LES
NORMES : ASTM E 1509, ULC/ORD1482-M90, ULC S627
DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES
CÔTÉ
6”
ARRIÈRE
3”
COIN
2”
PLAFOND
48”
IDÉBIT D’ALIMENTATION
MIN.
1.5
LB/H
MAX.
4.5
LB/H
CARACTÉRISTIQUES ÉLECTRIQUES
120 V
60 Hz
3”
2”
Tee
Interior
Vertical
Vent
DATE CODE / DE DATE
6”
6”
6”
Floor
Protection
6”
6”
Protection de
plancher
Installations
à travers le
mur
Protection de
plancher
Évents à
travers le
mur
Coude
45°
Té
Protection de
plancher
Évents
verticaux
intérieurst
Protection de
plancher
Évents
verticaux
intérieurs
Té
3”
6”
6”
45°
2”
2”
6”
2”
2”
3”
2”
6”
6”
6”
6”
6”
Stove rating plate illustrated
For rating plate location, see “INSTALLATION OVERVIEW” section.