3.6 MOBILE HOME INSTALLATION
29.4A
Installation into a manufactured home or mobile home should be installed in
accordance with the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard,
CAN/CSA Z240 MH Series, in Canada.
The appliance must be grounded to the steel chassis of the mobile home
(Some states do not require this; check with your local building department).
!
WARNING
DO NOT INSTALL IN A SLEEPING ROOM.
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING ROOF
MUST BE MAINTAINED.
3.5 OUTSIDE
AIR
Available from your Authorized Dealer (114KT)
Outside air must not be drawn from an enclosed space (garage, unventilated crawl space).
NOTE: Wolf Steel Ltd. strongly suggests using outside air for all residential installations, especially for
those that are energy ef
fi
cient, air-tight homes.
Outside air supply must not be over 15' long.
Outside air vents must be made with 1 3/4" diameter or larger metal or aluminum duct with a metal screen
attached to the end to keep out rodents (P.V.C. or other materials may not be used).
The outside air inlet must not be above or within 12" of the chimney termination, must have a rain cap or down-
turned elbow to prevent the water from entering and be located so that it will not become plugged by snow or
other material.
Outside air is required for all combustible built-in enclosure installations.
STOVE
ILLUSTRATED
The appliance must be installed on a non-combustible
fl
oor protector extending the full depth of the appliance
and extending a minimum 6" in front and on either side (minimum .018" thick - 26 gauge) of the fuel loading
and ash removal openings.
The
fl
oor protector must extend under and 2" beyond each side and rear of a "Tee" (if used).
NOTE: Floor protection is required for spark and ash shielding, but not for limiting
fl
oor temperatures
from the radiant heat of the appliance. The appliance was designed and safety tested so that without
any protection, the
fl
oor would not overheat.
Refer to local building codes for suitable
fl
oor protection materials.
3.4 FLOOR PROTECTION REQUIREMENTS