background image

20 

 

 

            Picture 28. 

 

SUB MENU M2-2- Daily program 

Pick the M2-2 

– daily program with pressing P3 to get different options of daily programing. 

 

 

Picture 29. 

 
You  can  set  up  two  working  groups,  the  first  with  START  STOP1  Day  1  and  the  second  with 
START2 Day and STOP2 Day, delimited by the times set according to the following  table. Option 
OFF indicates to clock to ignore given command. To change set point, use the P1 and P2. Press 
P3 to confirm. 

 

DAILY PROGRAM 

SUB MENU 

OPTION 

EXPLANATION 

PossibleSetting points 

M2-2-01 

Daily programing 

Activate 

0n/off 

M2-2-02 

Start 1 Day 

Time of activation 

OFF-0-23:50 

M2-2-03 

Stop 1 Day 

Time of deactivation 

OFF-0-23:50 

M2-2-04 

Start 2 Day 

Time of activation 

OFF-0-23:50 

M2-2-05 

Stop Day 

Time of deactivation 

OFF-0-23:50 

 
SUB MENU M2-3-Weekly program 

 

Menu M2-3-Weekly program enable to activate and deactivate and to set  weekly program of  the 
stove.  Weekly  program  has  4  independent  programs.  Sett  OFF  in  appropriate  field  in  order  to 
make clock to ignore appropriate command. 
Belowe listed tables tables describe th way of weekly program functioning.  
To enter the advanced version, to confirm set parameters and to exit program, press P3. 

 

 

SUB MENU 

OPTION 

EXPLANATION 

Possible setting points 

M2-3-01 

Weekly program 

Activate weekly 

programing 

On/off 

 

PROGRAM 1 

SUB MENU 

OPTION 

EXPLANATION 

Possible seting points 

M2-3-02 

Start Prg 1 

Activation period 

OFF-0-23:50 

Summary of Contents for RITTIUM 7

Page 1: ...RITTIUM 6 pellet stove RITTIUM 7 pellet stove Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION RITTIUM 6 RITTIUM 7 EN 14785 2006...

Page 2: ...T SETTING 14 7 6 CHANGE OF ROOM TEMPERATURE 14 7 7 ACHIEVING OF SET ROOM TEMPERATURE 14 7 8 STAND BY MODE 15 7 9 TURNING OFF THE STOVE 16 8 MENU 16 8 1 MENU STRUCTURE 16 8 2 TIME SETTING 18 8 3 MENU M...

Page 3: ...ls or using electricity the use of pellets is much more cost effective Pellet takes up far less space than coal and firewood 1 1 QUALITY OF PELLET The quality of pellets is of great importance for the...

Page 4: ...usted and programmed by an adult Errors or incorrect settings may cause hazardous conditions and or malfunction Do not place laundry on the stove to dry Clothes papers and similar items should be kept...

Page 5: ...ight RITTIUM 6 kg 116 Weight RITTIUM 7 kg 115 Fuel Wood pellet 6 mm L 30mm Exhaust diameter mm 80 Draft Pa 12 2 Storage capacity kg 15 Voltage V 230 15 Frequency Hz 50 Electrical power during the oper...

Page 6: ...6 RITTIUM 6 RITTIUM 7 Picture 1 Dimensions 1 Air inlet 50mm 2 Exhaust 80mm 1 Air inlet 50mm 2 Exhaust 80mm...

Page 7: ...l unit and display 2 Fire box doors 11 Storage cover 3 Door glass 12 Zadnja strana 4 Door handle 13 Exhaust 5 Vrata pepeljare 14 Primary air inlet 6 Ashtray 15 Main switch with Socket 7 Burning pot 16...

Page 8: ...smoke drain where is also a power connection The stove should be away from any possible obstacles like presented in Picture 4 Picture 4 Stove should be set 200 mm away from the obstacle on its sides...

Page 9: ...blem in between If the flame sways toward the mouth of the chimney there is quite sufficient air movement All irregularities in the functioning of the chimney must be removed before initializing the s...

Page 10: ...emperature setting Decrease room temperature Temperature setting Increase room temperature ON OFF Starting on and turning off the stove Programming Decrease chosen parameter Programming Increase chose...

Page 11: ...MING Selected parameter REMOTE CONTROL Infrared remote control is intended for everyday use when stove is fully configured and functional It should be used for turning ON OFF the stove and for setting...

Page 12: ...ust fan will be operational always when stove is ON but also it will continue to work after the stove is OFF Picture 8 Appereance on display ON 7 2 INITIAL PELLET LOADING LOAD PELLET AND STARTING FIRE...

Page 13: ...erature is set by pressing P1 Exhaust gases temperature continue to grow and when it reach next set point determined by parmaeters convection fan starts to blow convection fan indicator on display wil...

Page 14: ...ure press P1 Display will show current temperature by pressing P1 and P2 it is possible to increase and decrase temperature After 5 seconds or by pressing P3 control unit is accepting new set points a...

Page 15: ...convection fan will turn off after the set point of exhaust gases temperature 60 C is reached Led indicator ON OFF is blinking as shown in picture 17 Picture 17 Display appearance WAIT COOLING Tempera...

Page 16: ...etermined by technical parameter Exhaust fan is last to turn OFF Display will show OFF Picture 20 Display appearance OFF 8 MENU Enter MENU by pressing P1 MENU is is organized in different levels which...

Page 17: ...Prg 2 On off 15 Wednesday Prg 2 On off 16 Thursday Prg 2 On off 17 Friday Prg 2 On off 18 Saturday Prg 2 On off 19 Sunday Prg 2 On off 20 start Prg 3 Off 0 23 50 21 Stop Prg 3 Off 0 23 50 22 Monday P...

Page 18: ...tion 01 Enter with password set M9 01 exit set 8 2 TIME SETTING Time and date setting Thanks to battery internal clock is autonomus approx 5 years To enter general programing manu press P1 for 2 secon...

Page 19: ...ENU M2 1 PROGRAMING THE STOVE SUB MENU M1 2 Activation of stove programing Menu M2 set hrono enables you to activate all functions of time programing To activate this menu press P3 By pressing P1 and...

Page 20: ...M2 2 03 Stop 1 Day Time of deactivation OFF 0 23 50 M2 2 04 Start 2 Day Time of activation OFF 0 23 50 M2 2 05 Stop Day Time of deactivation OFF 0 23 50 SUB MENU M2 3 Weekly program Menu M2 3 Weekly p...

Page 21: ...d Stop 1 weekend final customer is able to set operating the stove on Satruday Operating of stove oon Sunday is enabeled with Start 2 weekend and Stop 2 veekend WEEKEND PROGRAM SUB MENU OPTION EXPLANA...

Page 22: ...vailable only when stove is turned OFF It enable loading of pellet by auger during initilalizing stove after the storage was left empty After opting M6 display will show PRESS PLUS Picture 33 Press P2...

Page 23: ...cture 35 Picture 35 9 ALARMS AND SOUND ALERTS If some misconduct durin stove opearation appear control uinit signalize the problem with led indicator and sound alerts List of alarms ALARM Display appr...

Page 24: ...l turn ON if active Display will show Al 2 alar al 2 and stove will shut down OVERHEATING OF EXHAUST GASES This alarm will turn ON if exhaust fan probe indicate higher temperature than usual Display w...

Page 25: ...a glass cleaning and cleaning of glass cups where the burning rocesstakes place The ash remained in the cup put away from flammable elements in order to prevent possible remains of some incandescent...

Page 26: ...26 Picture 36 Schedule of disassembling because of monthly cleaning...

Page 27: ...iged to provide spare parts in due time after the stove is no longer produced This warranty does not cover damage caused by inadequate use of stoves violating the instructions given in this manual mec...

Page 28: ...28 TIM SISTEM d o o Prva industrijska 9 22 330 Nova Pazova Serbia tel fax 381 22 32 80 76 e mail office timsistem rs www timsistem rs...

Reviews: