23
8.8 MENU M7- CURRENT STATUS
After entering menu M7, by pressing P3, Display will show certain variables of the current status.
Example of visual presentation is listed below.
Status
Explanation
3,1"
Auger mode durin uploading pellet
52
΄
Time out
T off
Status of of thermostat
106
ͦ
Temperature of exhaust gases
1490
Exhaust gases fan speed
8.9 MENI M8- TECHNICAL CALIBRATION
This option is available to technical personal only
8.10 MENU M9
– EXIT
By pressing P3 you will exit the current menu and enter the previous one. It is presented with
Picture 35.
Picture 35.
9. ALARMS AND SOUND ALERTS
If some misconduct durin stove opearation appear, control uinit signalize the problem with led
indicator and sound alerts.
List of alarms:
ALARM:
Display appreance*
No electricity
Al1 ALAR AL1 BLAC-OUT
Exhaust fan temperature probe
Al2 ALAR AL2 SONDA FUMI
Exhaust gases overheating
Al3 ALAR AL3 HOT FUMI
Exhaust fan encoder malfuction
Al4 ALAR AL4 ASPIRAT GUASTO
Stove did not started
Al5 ALAR AL5 MANCATA ACCENS
Lack of pellet fuel
Al6 ALAR AL6 MANCANO PELLET
Overheating safety thermostat
Al7 ALAR AL7 SICUREC TERMICA
Lack of pressure
Al8 ALAR AL8 MANCA DEPRESS
*-Display appereance is presented in Italian language (basic version).
Each above mentiond alarm is followed by shutting the stove OFF.